| Literature DB >> 26702546 |
Abstract
The Cutshall transmission method of determination of self-attenuation correction in (210)Pb measurements by gamma-spectrometry gives the results burdened with errors of up to 10%. The author proposes introducing into the Cutshall correction Cs,Cuts an additional revision factor CCs,Cuts to eliminate errors. The proposed formula of the revision factor describes the CCs,Cuts value depending on the experimentally obtained Cs,Cuts correction. Formula holds true in wide ranges of the measurement geometries and linear attenuation coefficients of both the standard and the sample.Entities:
Keywords: (210)Pb; Cutshall method; Gamma-ray spectrometry; Monte Carlo simulation; Self-attenuation
Year: 2015 PMID: 26702546 DOI: 10.1016/j.apradiso.2015.11.092
Source DB: PubMed Journal: Appl Radiat Isot ISSN: 0969-8043 Impact factor: 1.513