Hepatic Relaxation Times from Postmortem MR Imaging of Adult Humans.

Seiji Shiotani1, Tomoya Kobayashi, Hideyuki Hayakawa, Kazuhiro Homma, Harumi Sakahara.   

Abstract

PURPOSE: To measure T1 and T2 values of hepatic postmortem magnetic resonance (PMMR) imaging.
MATERIALS AND METHODS: We performed hepatic PMMR imaging of 22 deceased adults (16 men, 6 women; mean age, 56.3 years) whose deaths were for reasons other than liver injury or disease at a mean of 27.7 hours after death. Before imaging, the bodies were kept in cold storage at 4°C (mean rectal temperature, 17.6°C). We measured T1 and T2 values in the liver at two sites (the anterior segment of the right lobe and the lateral segment of the left lobe). We also investigated the influence of the body temperature and postmortem interval on T1 and T2 values.
RESULTS: In the anterior segment of the right lobe and the lateral segment of the left lobe, T1 values of PMMR imaging were 524 ± 112 ms and 472 ± 104 ms (mean ± standard deviation), respectively; while T2 values were 42 ± 6 ms and 43 ± 8 ms, respectively. T1 and T2 values did not differ significantly between the two sites (P ≧ 0.05). Regarding temperature, the T2 values of hepatic PMMR imaging were linearly correlated with the body temperature, but the T1 values were not. The T1 and T2 values of the two sites in the liver did not correlate with the postmortem interval.
CONCLUSION: Reduction in body temperature after death is considered to induce T1 and T2 value changes in the liver on PMMR imaging.

Entities:  

Mesh:

Year:  2015        PMID: 26701693      PMCID: PMC5608124          DOI: 10.2463/mrms.mp.2015-0086

Source DB:  PubMed          Journal:  Magn Reson Med Sci        ISSN: 1347-3182            Impact factor:   2.471


Introduction

While the worldwide decline in the rate of conventional autopsies has increased the need for and frequency of postmortem imaging as a complementary, supplementary, or alternative method of autopsy,[1-8] there continues to be insufficient postmortem imaging data for some parts of the human body due to lack of data obtained at various imaging settings. Postmortem magnetic resonance (PMMR) imaging can provide more detailed information with better contrast resolution than postmortem computed tomography (PMCT), and depict some pathological conditions that are difficult to identify with PMCT.[9] However, PMMR imaging has revealed that both MR signals and image contrast change after death, which can deteriorate diagnostic accuracy.[9-13] The optimization of parameters for PMMR imaging and accurate interpretation of imaging findings require analyses of quantitative data.[14-16] T1 and T2 values on MR imaging of the human adult liver in vitro and in vivo have been reported.[17-22] We surmised that the quantitative data of T1 and T2 values of hepatic PMMR imaging of in vivo would help interpret postmortem imaging variation relative to postmortem interval (time elapsed after death), functional failure before death, and/or metabolic abnormality resulting from pharmacologic or toxic substances. A newly published first-impression postmortem study using a 3.0T scanner reported that different magnetic field strengths, such as 1.5T, would result in different quantitative values for T1 and T2 for the same tissue and temperature.[16] We report the T1 and T2 values of 1.5T PMMR imaging of an adult human liver in vivo.

Materials and Methods

Subjects

We examined PMMR imaging data of 22 adults (16 men, 6 women; aged 27–83 years, mean: 56.3 years) who died suddenly and unexpectedly and did not have abnormal results nor indications of fatty liver on hepatopathological examination. Both ascites around the liver and putrefaction gas formation were ruled out using whole-body PMCT immediately before PMMR imaging. Their bodies were kept in cold storage at 4°C and subjected to PMMR imaging 7 to 96 hours after the confirmation of death (mean: 27.7 hours). Their rectal temperatures, measured immediately after PMMR imaging with an industrial thermometer (7-257-01, AS ONE Corp., Osaka, Japan), were 5–31°C (mean: 17.6°C). Autopsy was performed on each subject after PMMR imaging. Causes of death were 5 cases of trauma not involving the abdomen (cervical injuries due to road traffic accidents), 5 cases of ischemic heart disease (coronary arterial thrombus and/or myocardial infarction), 5 cases of acute heart failure due to fatal arrhythmia, 3 cases of drowning in the bathtub, 2 cases of cerebral hemorrhage, and 1 case each of subarachnoid hemorrhage and acute drug intoxication.

Scan conditions

With the permission of our institutional ethics committee, we performed PMMR imaging using a 1.5T MR imaging clinical scanner (Avanto, Siemens, Erlangen, Germany) with a dedicated 6-channel body matrix coil and spine matrix coil. We measured T1 and T2 values with a relaxation time map creation tool (syngo MapIt, Siemens, Erlangen, Germany).[23] Table 1 shows the scan parameters for the liver. A dual-flip angle technique based on the 3D-FLASH spoiled gradient echo sequence was employed for T1 mapping. T2 mapping was based on a multi-echo spin echo sequence. However, the first echo was ignored in the pixel-wise calculation of the T2 map, since it consistently yielded a lower signal than the second echo. Inhomogeneity correction was performed for static magnetic field (B0); however, it was not performed for radiofrequency magnetic field (B1).
Table 1.

Scan parameters of postmortem magnetic resonance (PMMR) imaging based on the syngo MapIt method

Scan parametersT1 map (GE)T2 map (SE)
TR/TE (ms)15/1.622000/30, 60, 90, 120, 150
Flip angle5°, 26°180°
Slice thickness/gap (mm)3/05/1
Matrix size (mm)1.2 × 1.21.2 × 1.2
Field of view (FOV) (mm)300300
Scan time (min)2.13.6
Number of slices22 (3D)11

GE, gradient echo; SE, spin echo; TR, repetition time; TE, echo time; 3D, three-dimensional

Analyses

A radiological technologist (T.K.) with 16 years of experience defined 2-cm-diameter circular regions of interest (ROIs) in the liver in both the anterior segment of the right lobe and the lateral segment of the left lobe excluding the vessels and bile ducts on axial images at the level of the main trunk of the portal vein (Fig. 1).
Fig. 1.

Postmortem 1.5T magnetic resonance (MR) image of the liver. Red circles indicate regions of interest (ROIs) placed at the level of the main trunk of the portal vein on postmortem MR images. ROIs were placed on the anterior segment of the right lobe and lateral segment of the left lobe.

Statistical analyses were performed using statistical software (Excel 2010, Microsoft, Redmond, WA, USA) with Statcel 2 (OMS, Tokyo, Japan) an add-in software. Parametric statistics (arithmetic mean value ± standard deviation [SD]) and Student’s t-test were used with a significance value of P < 0.05 for group differences. The relationships among T1 values, T2 values, and rectal temperatures were analyzed with Pearson’s correlation coefficient using the least squares methods. Also, the relationships among T1 values, T2 values, and postmortem intervals were analyzed using the same methods.

Results

A diagnostic radiologist (S.S.) with 24 years of experience observed no specific abnormality, except for signal intensity and contrast, between PMMR imaging (Fig. 2a–d) and clinical MR imaging of the liver. The T1 values of the anterior segment of the right lobe and the lateral segment of the left lobe were 524 ± 112 ms and 472 ± 104 ms (means ± SD), respectively (Table 2), showing no significant difference between the two sites (P = 0.123, t = 1.575 < 2.018 = t0.05(42)). The T2 values of the anterior segment of the right lobe and the lateral segment of the left lobe were 42 ± 6 ms and 43 ± 8 ms, respectively (Table 2), showing no significant difference between the two sites (P = 0.823, t = 0.225 < 2.018 = t0.05(42)).
Fig. 2.

(a) Coronal T1-weighted image of the liver on postmortem magnetic resonance imaging (MRI). T1 value of the anterior segment of the right lobe and lateral segment of the left lobe is 474.3 and 571.9 ms (rectal temperature: 27.5°C). (b) Coronal T2-weighted image of the liver on postmortem MRI. T1 value of the anterior segment of the right lobe and lateral segment of the left lobe is 57.7 and 54.0 ms (rectal temperature: 27.5°C). (c) Coronal T1-weighted image of the liver on postmortem MRI. T2 value of the anterior segment of the right lobe and lateral segment of the left lobe is 500.5 and 401.5 ms (rectal temperature: 5.0°C). (d) Coronal T2-weighted image of the liver on postmortem MRI. T2 value of the anterior segment of the right lobe and lateral segment of the left lobe is 29.9 and 26.8 ms (rectal temperature: 5.0°C).

Table 2.

T1 and T2 values (ms) in the anterior segment of the right lobe and the lateral segment of the left lobe on hepatic postmortem magnetic resonance imaging

T1 value (ms)T2 value (ms)
Anterior segment of the right lobe524 ± 11242 ± 6
Lateral segment of the left lobe472 ± 10443 ± 8

No significant difference is found between the two sites. (T1: P = 0.123, T2: P = 0.823).

Regarding rectal temperature, with hepatic PMMR imaging, T1 values of the anterior segment of the right lobe did not correlate significantly with the temperature (correlation coefficient r = 0.23; P > 0.05, Fig. 3); nor did T1 values of the lateral segment of the left lobe correlate significantly with the temperatures (r = 0.13; P > 0.05, Fig. 4). In contrast, T2 values of the anterior segment of the right lobe (r = 0.45; P < 0.05, Fig. 5) and T2 values of the lateral segment of the left lobe (r = 0.52; P < 0.05, Fig. 6) significantly correlated with the rectal temperature.
Fig. 3.

Relationship between T1 values of the anterior segment of the right lobe and rectal temperature of deceased subjects.

Fig. 4.

Relationship between T1 values of the lateral segment of the left lobe and rectal temperature of deceased subjects.

Fig. 5.

Relationship between T2 values of the anterior segment of the right lobe and rectal temperature of deceased subjects.

Fig. 6.

Relationship between T2 values of the lateral segment of the left lobe and rectal temperature of deceased subjects.

Regarding postmortem interval, with hepatic PMMR imaging, T1 values of the anterior segment of the right lobe (correlation coefficient r = −0.26; P > 0.05, Fig. 7) and T1 values of the lateral segment of the left lobe (r = −0.28; P > 0.05, Fig. 8) did not correlate significantly with the postmortem interval. Also, T2 values of the anterior segment of the right lobe (r = −0.29; P > 0.05, Fig. 9) and T2 values of the lateral segment of the left lobe (r = −0.38; P > 0.05, Fig. 10) did not correlate significantly with the postmortem interval.
Fig. 7.

Relationship between T1 values of the anterior segment of the right lobe and postmortem interval of deceased subjects.

Fig. 8.

Relationship between T1 values of the lateral segment of the left lobe and postmortem interval of deceased subjects.

Fig. 9.

Relationship between T2 values of the anterior segment of the right lobe and postmortem interval of deceased subjects.

Fig. 10.

Relationship between T2 values of the lateral segment of the left lobe and postmortem interval of deceased subjects.

Discussion

In the present study, the average T1 values of the anterior segment of the right lobe and the lateral segment of the left lobe on hepatic PMMR imaging at 1.5T were 524 ± 112 ms and 472 ± 104 ms, respectively. The average T2 values of those two sites were 42 ± 6 ms and 43 ± 8 ms, respectively. T2 values of the two sites linearly correlated with the body temperature, but T1 values did not. T1 and T2 values of the two sites did not correlate with the postmortem interval. Zech et al. reported T1 and T2 values of hepatic PMMR imaging at 3.0T were 680 and 37 ms.[16] De Bazelaire et al. reported that T1 values were generally higher and T2 values were generally lower at 3.0T than at 1.5T in the clinical MR imaging,[22] which agree with the results of our study and those of Zech et al. In the report of de Bazelaire et al., four healthy adult volunteers underwent MR imaging with a whole-body 1.5T MR scanner with a receive-only surface coil array, and T1 and T2 values of the liver were measured using an inversion-recovery method with different inversion times and a multiple spin-echo technique with different echo times.[22] Average T1 and T2 values of their living subjects’ livers were 586 ± 39 ms and 46 ± 6 ms, respectively. Comparing measured T1 and T2 values between our deceased subjects and living subjects in the report of de Bazelaire et al.,[22] hepatic PMMR imaging showed a significantly shorter T1 value of the lateral segment of the left lobe, but no significant differences were noted in the anterior segment of the right lobe and T2 values of the both sites. In the liver after death, decomposition and cooling[24] affects T1 and T2 values of MR imaging due to changes in the components and property of the liver, including fat, water, and paramagnetic substances such as iron,[25] all of which are expressed as relaxation time changes of the entire liver. In a living body, motion-induced imaging artifacts occur due to pulsatile blood flow; thus, deviations in the measurement of T1 and T2 values are normalized. However, with PMMRI, T1 and T2 values do not include such artifacts. As decomposition occurs after death, the increase of phosphoric, carbonic, fatty, and lactic acids induces acidosis of the liver and reduces the pH.[26,27] Investigating the livers of rats, Moser et al. reported that reduction of the pH caused the prolongation of T2 values, though they did not mention T1 values.[28] We suggest that pH reduction in the postmortem human liver can cause the prolongation of T2 values. The increased water content of tissues causes the elevation of T1 and T2 values,[29] although those of the liver are not the focus of attention in our study. Following death, the brain shows a time-course increase in water content due to the absorption of spinal fluid around the brain.[30,31] This is attributed to increased lactic acid as a result of anaerobic glycolysis and increased osmotic pressure due to an increased number of proteins caused by autolysis in the ischemic brain.[32-34] However, the liver in our study is considered not to have shown increased water content for a similar reason, because none of our cases exhibited ascites around the liver. An increase in the water content of the liver is known to sometimes occur with a prolonged agonal stage,[35] although this does not apply to our study since we investigated sudden death cases. The Bloembergen-Purcell-Pound theory states that changes in T1 and T2 values are related to temperature change.[36] Therefore, the cooling of the body after death and subsequent storage of the cadaver in a refrigerator are considered to be the causes of MR relaxation time changes. Within a small temperature range, the T1 value depends linearly on the temperature in fat and water.[14,15,37-41] The T2 value decreases with a declining temperature in fat tissue and aqueous solutions;[37,40,41] however, the temperature dependence of the T2 value can be masked by other factors in tissue.[37] The magnetic susceptibility of a paramagnetic substance is inversely proportional to the absolute temperature according to Curie’s law (magnetic susceptibility χ = C/T, where C is a constant and T is the absolute temperature).[37] The liver contains some paramagnetic substances such as iron, manganese, and copper.[42-44] The increased magnetic susceptibility associated with temperature reduction induces changes in the relaxation time and has a very weak T1-shortening effect but strong T2-shortening effect.[45] In the liver of our PMMR imaging, T1 values were shorter than the reported clinical MR imaging[22] in the lateral segment of the left lobe, but not much difference was found in the anterior segment of the right lobe. This T1-shortening effect is due to the effect of fat and water at low temperatures. However, T1 values on hepatic PMMR imaging did not correlate significantly with the rectal temperature. Matsumoto et al.[38] reported that the T1 value of a pig liver in vitro decreased linearly with a temperature reduction range of 10–50°C, although the T1 value increased between the range of 0–10°C. Moser et al.[28] reported that in a temperature below 37°C, at 4 hours after biopsy excision, T1 values were higher in a rat liver in vitro at 22, 15, 30, 7, and 37°C, in this order. Namely, T1 value reduction was not proportional to the temperature reduction. In our study, the T1 value of the postmortem liver varied at low temperature over a similar range, which is considered to be the reason for not showing linearity regarding the relationship between the T1 value and rectal temperature. Regarding T2 values, compared with clinical MR imaging of the liver, hepatic PMMR imaging did not show any significant change. For the liver, T2 prolongation due to a reduced pH, T2 shortening due to fat, water, and paramagnetic substances at low temperature negated each other. However, T2 values on hepatic PMMR imaging were correlated significantly with the rectal temperature. Also, according to Moser et al., at 4 hours after biopsy excision in a temperature below 37°C, high T2 values of a rat liver in vitro were observed at 37, 30, 22, 15, and 7°C in this decreasing order, showing the proportional reduction of T2 values relative to the temperature. In our study, the relationship between T2 value and rectal temperature of the liver showed linearity. With hepatic PMMR imaging, T1 values did not correlate significantly with the rectal temperature, but T2 values significantly correlated. On the other hand, with cerebral PMMR imaging, it has been known that T1 values correlates significantly with rectal temperature, though T2 values did not.[13] This discrepancy between hepatic and cerebral PMMR imaging suggests organ-specific MR relaxation times after death. Our study has four limitations. One is that we could not examine 1.5T MR imaging data of healthy volunteers, because an approximately 2-minute breath hold is necessary to obtain comparative imaging data. T1 and T2 values depend on the type of MR imaging unit and scan conditions; thus may differ on different imaging units or with different parameters.[23] In our study, we had to compare hepatic PMMR imaging data we generated with published data from clinical MR imaging of the liver in the literature. The second limitation is that the standard deviation of T1 value of our subjects were large compared to that of living subjects as reported by de Bazelaire et al.[22] Decomposition of the liver progresses in cases in which a long period of time elapsed after death. In our study, PMMR imaging was performed 7–96 hours after the confirmation of death. Our subjects had been kept in cold storage, which reduces decomposition of the body. Nevertheless, the wide deviation in the time after death may have caused differences of the degree of decomposition in each body, thereby resulting in increased standard deviation values. Also, a possible uneven rate of decomposition within the liver of a deceased subject may cause a difference in T1 shortening effects between the right anterior and left lateral segments of the liver. The third limitation is that B1 inhomogeneity correction was not performed with our relaxation time map creation tool, which is considered to have resulted in regional signal variation. A greater variation can be induced in the T1 map which is based on gradient echo sequences than the T2 map which is based on spin echo sequences. The fourth limitation is that we did not directly measure the pH, fat, water, and paramagnetic substances. Such measurement with an MR imaging system[46-48] would enable estimation of the level of effect of relaxation time changes of each factor on the total liver relaxation time.

Conclusion

In conclusion, with hepatic PMMR imaging, T1 values did not significantly correlate with the rectal temperature, but T2 values did correlate. Postmortem interval had no effect on T1 and T2 values on hepatic PMMR imaging. Reduction in body temperature after death is considered to induce T1 and T2 value changes on hepatic PMMR imaging.
  36 in total

1.  Relaxation induced by ferritin and ferritin-like magnetic particles: the role of proton exchange.

Authors:  Y Gossuin; A Roch; R N Muller; P Gillis
Journal:  Magn Reson Med       Date:  2000-02       Impact factor: 4.668

2.  Low paramagnetic-ion content in cancer cells: its significance in cancer detection by magnetic resonance imaging.

Authors:  G N Ling; T Kolebic; R Damadian
Journal:  Physiol Chem Phys Med NMR       Date:  1990

3.  Temperature dependence of relaxation times in proton components of fatty acids.

Authors:  Kagayaki Kuroda; Taku Iwabuchi; Makoto Obara; Masatoshi Honda; Kensuke Saito; Yutaka Imai
Journal:  Magn Reson Med Sci       Date:  2011       Impact factor: 2.471

Review 4.  MR thermometry.

Authors:  Viola Rieke; Kim Butts Pauly
Journal:  J Magn Reson Imaging       Date:  2008-02       Impact factor: 4.813

5.  The influence of body temperature on image contrast in post mortem MRI.

Authors:  Thomas D Ruder; Gary M Hatch; Lea Siegenthaler; Garyfalia Ampanozi; Sandra Mathier; Michael J Thali; Oliver M Weber
Journal:  Eur J Radiol       Date:  2011-03-31       Impact factor: 3.528

6.  Magnetic resonance microscopy of chemically fixed human embryos at high spatial resolution.

Authors:  Yosuke Otake; Shinya Handa; Katsumi Kose; Kohei Shiota; Shigehito Yamada; Chigako Uwabe
Journal:  Magn Reson Med Sci       Date:  2015-02-12       Impact factor: 2.471

7.  Temperature relationships of proton spin-lattice relaxation time T1 in biological tissues.

Authors:  C J Lewa; Z Majewska
Journal:  Bull Cancer       Date:  1980       Impact factor: 1.276

8.  Characteristic signal intensity changes on postmortem magnetic resonance imaging of the brain.

Authors:  Tomoya Kobayashi; Seiji Shiotani; Kazunori Kaga; Hajime Saito; Kousaku Saotome; Katsumi Miyamoto; Mototsugu Kohno; Kazunori Kikuchi; Hideyuki Hayakawa; Kazuhiro Homma
Journal:  Jpn J Radiol       Date:  2010-01-30       Impact factor: 2.374

9.  Relationship between acidity and swelling in the brain.

Authors:  K Takahashi
Journal:  Tohoku J Exp Med       Date:  1966-11       Impact factor: 1.848

10.  Chemical exchange saturation transfer (CEST): what is in a name and what isn't?

Authors:  Peter C M van Zijl; Nirbhay N Yadav
Journal:  Magn Reson Med       Date:  2011-02-17       Impact factor: 4.668

View more
  3 in total

1.  Temperature-corrected post-mortem 1.5 T MRI quantification of non-pathologic upper abdominal organs.

Authors:  Nicole Schwendener; Christian Jackowski; Frederick Schuster; Anders Persson; Marcel J Warntjes; Wolf -Dieter Zech
Journal:  Int J Legal Med       Date:  2017-06-17       Impact factor: 2.686

2.  Temperature-corrected postmortem 3-T MR quantification of histopathological early acute and chronic myocardial infarction: a feasibility study.

Authors:  Anders Persson; John Baeckmann; Johan Berge; Christian Jackowski; Marcel Warntjes; Wolf-Dieter Zech
Journal:  Int J Legal Med       Date:  2017-06-13       Impact factor: 2.686

3.  T2 and T2 mapping in ex situ porcine myocardium: myocardial intravariability, temporal stability and the effects of complete coronary occlusion.

Authors:  Bridgette Webb; Martin Manninger; Marlene Leoni; Thomas Widek; Martin Dobrovnik; Daniel Scherr; Rudolf Stollberger; Thorsten Schwark
Journal:  Int J Legal Med       Date:  2019-12-18       Impact factor: 2.686

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.