Literature DB >> 26701659

Standardisation and precise determination of the half-life of (44)Sc.

E García-Toraño1, V Peyrés2, M Roteta2, A I Sánchez-Cabezudo2, E Romero3, A Martínez Ortega3.   

Abstract

The half-life of the positron-emitter (44)Sc has been determined by following the decay rate with two measurement systems; an Ionisation Chamber and a HPGe detector. The combination of seven results gives a value of T1/2=4.042 (25)h, about 2% higher than the recommended value of T1/2=3.97 (4)h (Browne, 2011) and with a lower uncertainty. This radionuclide has also been standardised by coincidence counting, and liquid scintillation counting techniques. A (44)Ti/(44)Sc generator developed at CIEMAT was used to obtain the (44)Sc solutions used in all measurements.
Copyright © 2015 Elsevier Ltd. All rights reserved.

Keywords:  Half-life; Positron emitters; Sc-44; Standardisation

Mesh:

Substances:

Year:  2015        PMID: 26701659     DOI: 10.1016/j.apradiso.2015.12.007

Source DB:  PubMed          Journal:  Appl Radiat Isot        ISSN: 0969-8043            Impact factor:   1.513


  7 in total

1.  44Sc-PSMA-617 for radiotheragnostics in tandem with 177Lu-PSMA-617-preclinical investigations in comparison with 68Ga-PSMA-11 and 68Ga-PSMA-617.

Authors:  Christoph A Umbricht; Martina Benešová; Raffaella M Schmid; Andreas Türler; Roger Schibli; Nicholas P van der Meulen; Cristina Müller
Journal:  EJNMMI Res       Date:  2017-01-19       Impact factor: 3.138

2.  47Sc as useful β--emitter for the radiotheragnostic paradigm: a comparative study of feasible production routes.

Authors:  Katharina A Domnanich; Cristina Müller; Martina Benešová; Rugard Dressler; Stephanie Haller; Ulli Köster; Bernard Ponsard; Roger Schibli; Andreas Türler; Nicholas P van der Meulen
Journal:  EJNMMI Radiopharm Chem       Date:  2017-06-02

3.  Production and separation of 43Sc for radiopharmaceutical purposes.

Authors:  Katharina A Domnanich; Robert Eichler; Cristina Müller; Sara Jordi; Vera Yakusheva; Saverio Braccini; Martin Behe; Roger Schibli; Andreas Türler; Nicholas P van der Meulen
Journal:  EJNMMI Radiopharm Chem       Date:  2017-11-25

4.  Therapeutic Potential of 47Sc in Comparison to 177Lu and 90Y: Preclinical Investigations.

Authors:  Klaudia Siwowska; Patrycja Guzik; Katharina A Domnanich; Josep M Monné Rodríguez; Peter Bernhardt; Bernard Ponsard; Roger Hasler; Francesca Borgna; Roger Schibli; Ulli Köster; Nicholas P van der Meulen; Cristina Müller
Journal:  Pharmaceutics       Date:  2019-08-20       Impact factor: 6.321

5.  Developments toward the Implementation of 44Sc Production at a Medical Cyclotron.

Authors:  Nicholas P van der Meulen; Roger Hasler; Zeynep Talip; Pascal V Grundler; Chiara Favaretto; Christoph A Umbricht; Cristina Müller; Gaia Dellepiane; Tommaso S Carzaniga; Saverio Braccini
Journal:  Molecules       Date:  2020-10-14       Impact factor: 4.411

Review 6.  Production of scandium radionuclides for theranostic applications: towards standardization of quality requirements.

Authors:  R Mikolajczak; S Huclier-Markai; C Alliot; F Haddad; D Szikra; V Forgacs; P Garnuszek
Journal:  EJNMMI Radiopharm Chem       Date:  2021-05-25

7.  Py-Macrodipa: A Janus Chelator Capable of Binding Medicinally Relevant Rare-Earth Radiometals of Disparate Sizes.

Authors:  Aohan Hu; Eduardo Aluicio-Sarduy; Victoria Brown; Samantha N MacMillan; Kaelyn V Becker; Todd E Barnhart; Valery Radchenko; Caterina F Ramogida; Jonathan W Engle; Justin J Wilson
Journal:  J Am Chem Soc       Date:  2021-06-30       Impact factor: 16.383

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.