Literature DB >> 26700692

MyPectus: First-in-human pilot study of remote compliance monitoring of teens using dynamic compression bracing to correct pectus carinatum.

Brittany Harrison1, Lily Stern2, Philip Chung2, Mozziyar Etemadi2, Dillon Kwiat2, Shuvo Roy2, Michael R Harrison2, Marcelo Martinez-Ferro3.   

Abstract

BACKGROUND: Patient compliance is a crucial determinant of outcomes in treatments involving medical braces, such as dynamic compression therapy for pectus carinatum (PC). We performed a pilot study to assess a novel, wireless, real-time monitoring system (MyPectus) to address noncompliance.
METHODS: Eight patients (10-16years old) with moderately severe PC deformities underwent bracing. Each patient received a data logger device inserted in the compression brace to sense temperature and pressure. The data were transmitted via Bluetooth 4.0 to an iOS smartphone app, then synced to cloud-based storage, and presented to the clinician on a web-based dashboard. Patients received points for brace usage on the app throughout the 4-week study, and completed a survey to capture patient-reported usage patterns.
RESULTS: In all 8 patients, the data logger sensed and recorded data, which connected through all MyPectus system components. There were occasional lapses in data collection because of technical difficulties, such as limited storage capacity. Patients reported positive feedback regarding points.
CONCLUSIONS: The components of the MyPectus system recorded, stored, and provided data to patients and clinicians. The MyPectus system will inform clinicians about issues related to noncompliance: discrepancy between patient-reported and sensor-reported data regarding brace usage; real-time, actionable information; and patient motivation.
Copyright © 2015 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Adherence; Compliance; Mobile; Orthotics; Pectus; Technology

Mesh:

Year:  2015        PMID: 26700692     DOI: 10.1016/j.jpedsurg.2015.11.007

Source DB:  PubMed          Journal:  J Pediatr Surg        ISSN: 0022-3468            Impact factor:   2.545


  2 in total

1.  Scoping Review of Healthcare Literature on Mobile, Wearable, and Textile Sensing Technology for Continuous Monitoring.

Authors:  N Hernandez; L Castro; J Medina-Quero; J Favela; L Michan; W Ben Mortenson
Journal:  J Healthc Inform Res       Date:  2021-02-01

2.  Orthotic Bracing or Minimally Invasive Surgery? A Summary of 767 Pectus Carinatum Cases for 9 Years.

Authors:  Ziyin Shang; Chun Hong; Xianlun Duan; Xiangyong Li; Yuan Si
Journal:  Biomed Res Int       Date:  2021-02-19       Impact factor: 3.411

  2 in total