Literature DB >> 26699032

Biosensor based on excessively tilted fiber grating in thin-cladding optical fiber for sensitive and selective detection of low glucose concentration.

Binbin Luo, Zhijun Yan, Zhongyuan Sun, Yong Liu, Mingfu Zhao, Lin Zhang.   

Abstract

We report a highly sensitive, high Q-factor, label free and selective glucose sensor by using excessively tilted fiber grating (Ex-TFG) inscribed in the thin-cladding optical fiber (TCOF). Glucose oxidase (GOD) was covalently immobilized on optical fiber surface and the effectiveness of GOD immobilization was investigated by the fluorescence microscopy and highly accurate spectral interrogation method. In contrast to the long period grating (LPG) and optical fiber (OF) surface Plasmon resonance (SPR) based glucose sensors, the Ex-TFG configuration has merits of nearly independent cross sensitivity of the environmental temperature, simple fabrication method (no noble metal deposition or cladding etching) and high detection accuracy (or Q-factor). Our experimental results have shown that Ex-TFG in TCOF based sensor has a reliable and fast detection for the glucose concentration as low as 0.1~2.5mg/ml and a high sensitivity of ~1.514 nm·(mg/ml)⁻¹, which the detection accuracy is ~0.2857 nm⁻¹ at pH 5.2, and the limit of detection (LOD) is 0.013~0.02 mg/ml at the pH range of 5.2~7.4 by using an optical spectrum analyzer with a resolution of 0.02 nm.

Entities:  

Year:  2015        PMID: 26699032     DOI: 10.1364/OE.23.032429

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  4 in total

1.  Optical fiber LPG biosensor integrated microfluidic chip for ultrasensitive glucose detection.

Authors:  Ming-Jie Yin; Bobo Huang; Shaorui Gao; A Ping Zhang; Xuesong Ye
Journal:  Biomed Opt Express       Date:  2016-04-28       Impact factor: 3.732

2.  A label-free fiber optic SPR biosensor for specific detection of C-reactive protein.

Authors:  Wenjia Wang; Zhigang Mai; Yuzhi Chen; Jiaqi Wang; Liang Li; Qingning Su; Xuejin Li; Xueming Hong
Journal:  Sci Rep       Date:  2017-12-04       Impact factor: 4.379

3.  Integration of Curved D-Type Optical Fiber Sensor with Microfluidic Chip.

Authors:  Yung-Shin Sun; Chang-Jyun Li; Jin-Cherng Hsu
Journal:  Sensors (Basel)       Date:  2016-12-30       Impact factor: 3.576

4.  Perspectives on Assembling Coronavirus Spikes on Fiber Optics to Reveal Broadly Recognizing Antibodies and Generate a Universal Coronavirus Detector.

Authors:  Marzhan Sypabekova; Daniele Tosi; Luca Vangelista
Journal:  Front Bioeng Biotechnol       Date:  2021-11-26
  4 in total