Literature DB >> 26698371

Experience and complications associated with use of guide extension catheters in percutaneous coronary intervention.

Thomas M Waterbury1, Paul Sorajja2, Malcolm R Bell1, Ryan J Lennon3, Verghese Mathew1, Mandeep Singh1, Gurpreet S Sandhu1, Rajiv Gulati1.   

Abstract

OBJECTIVES: To investigate the utility and safety of the GuideLiner "mother-and-child" catheter system during transradial and transfemoral percutaneous coronary intervention (PCI).
BACKGROUND: In patients with complex coronary anatomy, stent delivery can be challenging and result in procedural failure and complications. The GuideLiner is a coaxial guide extension system designed to enable deep vessel engagement and facilitate device delivery. The purpose of this study was to evaluate procedural success and safety in a series of GuideLiner-facilitated PCI.
METHODS: Single center retrospective study of PCI utilizing the GuideLiner catheter between February 2010 and October 2014. Patients who underwent PCI without GuideLiner use during the same time period were used as controls for comparison.
RESULTS: A total of 363 cases of GuideLiner-facilitated PCI were identified from 6,088 unique PCI procedures performed during this same time period. Patients in the GuideLiner group were older (mean age 71.5 vs. 67.8, P < 0.001) and had more multivessel disease (72% vs. 63%, P = 0.001) compared with controls. Type C lesions were present in 78% of GuideLiner cases. Procedural success resulting in successful device delivery with the GuideLiner catheter was 80.2%. Stent deformation associated with GuideLiner use occurred in 2.2% (8/363), with the incidence of this complication decreasing over device iterations. Coronary dissection attributed to GuideLiner occurred in 3.3% (12/363) and became less frequent over the study period.
CONCLUSIONS: In this consecutive series of GuideLiner supported PCI, the guide extension system enabled procedural success in the majority. A decline in device-associated complications over time may be attributed to operator learning curve, patient selection, and improvement in catheter design.
© 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

Entities:  

Keywords:  PCI complications; complex PCI; interventional devices

Mesh:

Year:  2015        PMID: 26698371     DOI: 10.1002/ccd.26329

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  3 in total

1.  Mother-Daughter-Granddaughter Double GuideLiner Technique for Delivering Stents Past Multiple Extreme Angulations.

Authors:  Matthew T Finn; Philip Green; William Nicholson; Sanjog Kalra; David E Kandzari; Nicholas Lembo; Craig A Thompson; Dimitri Karmpaliotis
Journal:  Circ Cardiovasc Interv       Date:  2016-08       Impact factor: 6.546

2.  Patient outcomes in GuideLiner facilitated percutaneous coronary intervention stratified by the SYNTAX score: A retrospective analysis.

Authors:  Shuangbo Liu; Christopher Parr; Hannah Zhang; Basem Elbarouni; Ashish Shah; Malek Kass; Amir Ravandi
Journal:  JRSM Cardiovasc Dis       Date:  2019-03-20

3.  GuideLiner Catheter Use for Percutaneous Intervention Involving Anomalous Origin of a Single Coronary Trunk Arising from the Ascending Aorta.

Authors:  Mitsunari Matsumoto; Yusuke Tamanaha; Yoshimasa Tsurumaki; Tomohiro Nakamura
Journal:  Case Rep Cardiol       Date:  2016-07-27
  3 in total