Literature DB >> 26697293

Applying Cross-Pin System in Both Femoral and Tibial Fixation in Anterior Cruciate Ligament Reconstruction Using Hamstring Tendons.

Wei Qi1, Yujie Liu1, Jing Xue2, Haifeng Li1, Junliang Wang1, Feng Qu1.   

Abstract

Use of the RigidFix Cross Pin System (DePuy Mitek, Raynham, MA) is a popular technique for femoral fixation of grafts in anterior cruciate ligament reconstruction (ACLR). However, tibial fixation is still limited to the use of interference screws and post fixation, and few surgeons apply the femoral RigidFix system in tibial fixation. Meanwhile, tunnel enlargement is still a problem that affects the outcome of ACLR with hamstring grafts. We have used the femoral RigidFix system in femoral and tibial fixation. The rod top of the guide frame should be placed under the level of the subchondral bone at the proximal end of the tibial tunnel to ensure that the pins will not be inserted into the joint. The pins are inserted through the center of the lateral tibia. Using our technique, the fixation points of the femur and tibia are close to the anterior cruciate ligament insertions, and full contact of the graft with the tunnel wall can be accomplished. On the basis of our preliminary observations and investigation, we are optimistic about the prospect of performing ACLR using the RigidFix system in femoral and tibial fixation.

Entities:  

Year:  2015        PMID: 26697293      PMCID: PMC4661547          DOI: 10.1016/j.eats.2015.03.018

Source DB:  PubMed          Journal:  Arthrosc Tech        ISSN: 2212-6287


  3 in total

1.  Tibial tunnel widening after anterior cruciate ligament reconstructions with hamstring tendons using Rigidfix femoral fixation and Intrafix tibial fixation.

Authors:  Nam-Hong Choi; Jung-Hoon Lee; Kyung-Mo Son; Brian N Victoroff
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-01       Impact factor: 4.342

2.  The results of reconstruction of the ACL using the cross-pin femoral system and four-strand hamstring tendon autografts.

Authors:  Uzeyir Tırmık; Mahir Mahiroğulları; Mesih Kuşkucu
Journal:  Acta Orthop Traumatol Turc       Date:  2011       Impact factor: 1.511

3.  Bioabsorbable interference screw versus bioabsorbable cross pins: influence of femoral graft fixation on the clinical outcome after ACL reconstruction.

Authors:  Stephan Frosch; Anne Rittstieg; Peter Balcarek; Tim Alexander Walde; Jan P Schüttrumpf; Martin M Wachowski; Klaus M Stürmer; Karl-Heinz Frosch
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-11       Impact factor: 4.342

  3 in total
  1 in total

1.  Femoral fixation methods for hamstring graft in anterior cruciate ligament reconstruction: A network meta-analysis of controlled clinical trials.

Authors:  Shixin Nie; Shuqing Zhou; Wei Huang
Journal:  PLoS One       Date:  2022-09-22       Impact factor: 3.752

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.