Literature DB >> 26696082

Dual-Energy CT: Basic Principles, Technical Approaches, and Applications in Musculoskeletal Imaging (Part 2).

Patrick Omoumi1, Francis R Verdun2, Roman Guggenberger3, Gustav Andreisek3, Fabio Becce1.   

Abstract

In recent years, technological advances have allowed manufacturers to implement dual-energy computed tomography (DECT) on clinical scanners. With its unique ability to differentiate basis materials by their atomic number, DECT has opened new perspectives in imaging. DECT has been successfully used in musculoskeletal imaging with applications ranging from detection, characterization, and quantification of crystal and iron deposits, to simulation of noncalcium (improving the visualization of bone marrow lesions) or noniodine images. Furthermore, the data acquired with DECT can be postprocessed to generate monoenergetic images of varying kiloelectron volts, providing new methods for image contrast optimization as well as metal artifact reduction. The first part of this article reviews the basic principles and technical aspects of DECT including radiation dose considerations. The second part focuses on applications of DECT to musculoskeletal imaging including gout and other crystal-induced arthropathies, virtual noncalcium images for the study of bone marrow lesions, the study of collagenous structures, applications in computed tomography arthrography, as well as the detection of hemosiderin and metal particles. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

Entities:  

Mesh:

Year:  2015        PMID: 26696082     DOI: 10.1055/s-0035-1569252

Source DB:  PubMed          Journal:  Semin Musculoskelet Radiol        ISSN: 1089-7860            Impact factor:   1.777


  14 in total

1.  Evaluation of glenoid labral tears: comparison between dual-energy CT arthrography and MR arthrography of the shoulder.

Authors:  Giovanni Foti; William Mantovani; Matteo Catania; Paolo Avanzi; Simone Caia; Claudio Zorzi; Giovanni Carbognin
Journal:  Radiol Med       Date:  2019-09-20       Impact factor: 3.469

Review 2.  Dual-energy CT: theoretical principles and clinical applications.

Authors:  Andrea Agostini; Alessandra Borgheresi; Alberto Mari; Chiara Floridi; Federico Bruno; Marina Carotti; Nicolò Schicchi; Antonio Barile; Stefania Maggi; Andrea Giovagnoni
Journal:  Radiol Med       Date:  2019-12-02       Impact factor: 3.469

3.  Assessment of cardiovascular risk profile based on measurement of tophus volume in patients with gout.

Authors:  Kyung-Ann Lee; Se-Ri Ryu; Seong-Jun Park; Hae-Rim Kim; Sang-Heon Lee
Journal:  Clin Rheumatol       Date:  2017-12-29       Impact factor: 2.980

4.  The effect of tube voltage combination on image artefact and radiation dose in dual-source dual-energy CT: comparison between conventional 80/140 kV and 80/150 kV plus tin filter for gout protocol.

Authors:  Ji Young Jeon; Sheen-Woo Lee; Yu Mi Jeong; Han Joo Baek
Journal:  Eur Radiol       Date:  2018-07-09       Impact factor: 5.315

5.  Coexisting sarcoidal granulomatous inflammation and diffuse tenosynovial giant cell tumor of the knee after a total knee replacement: a case report.

Authors:  Yaxia Zhang; Michael Joyce; Jean Schils; Thomas W Bauer
Journal:  Skeletal Radiol       Date:  2016-10-07       Impact factor: 2.199

6.  Initial experience with dual-energy computed tomography-guided bone biopsies of bone lesions that are occult on monoenergetic CT.

Authors:  Michael C Burke; Ankur Garg; Jonathan M Youngner; Swati D Deshmukh; Imran M Omar
Journal:  Skeletal Radiol       Date:  2018-10-20       Impact factor: 2.199

7.  Dual energy CT iodine map for delineating inflammation of inflammatory arthritis.

Authors:  Takeshi Fukuda; Yoshinori Umezawa; Akihiko Asahina; Hidemi Nakagawa; Kazuhiro Furuya; Kunihiko Fukuda
Journal:  Eur Radiol       Date:  2017-07-03       Impact factor: 5.315

8.  Single-source dual-energy computed tomography for the detection of bone marrow lesions: impact of iterative reconstruction and algorithms.

Authors:  N Engelhard; K G Hermann; J Greese; M Fuchs; M Pumberger; M Putzier; T Diekhoff
Journal:  Skeletal Radiol       Date:  2019-12-10       Impact factor: 2.199

9.  Dual-energy computed tomography of the neck-optimizing tube current settings and radiation dose using a 3D-printed patient phantom.

Authors:  Torsten Diekhoff; Michael Scheel; Wiebke Kress; Bernd Hamm; Paul Jahnke
Journal:  Quant Imaging Med Surg       Date:  2021-04

Review 10.  Dual-Energy CT: New Horizon in Medical Imaging.

Authors:  Hyun Woo Goo; Jin Mo Goo
Journal:  Korean J Radiol       Date:  2017-05-19       Impact factor: 3.500

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.