Literature DB >> 26695671

[Value of IL-6 and IL-8 in the diagnosis of neonatal sepsis].

Feng-Xia Zhao1, Guang-Hui Liu, Jian Zhang.   

Abstract

OBJECTIVE: To explore the significance of interleukin-6 (IL-6) and IL-8 in the diagnosis of neonatal sepsis.
METHODS: This was a prospective study conducted between August 2014 and February 2015. A total of 140 neonates who were suspected infectious were enrolled and classified into a sepsis group (n=49) and a local infection group (n=91). Sixty-one neonates who were non-infectious served as the control group. Serum levels of IL-6 and IL-8 were measured before treatment and 3 days after treatment. The value of serum IL-6 and IL-8 for the diagnosis of neonatal sepsis was assessed by receiver operating characteristic (ROC) curve analysis.
RESULTS: Before treatment, serum levels of IL-6 and IL-8 in the sepsis group were higher than those in the local infection and control groups (P<0.05), and the local infection group had higher serum levels of IL-6 and IL-8 than the control group (P<0.05). After three days of treatment, the serum IL-6 level in the sepsis group remained higher than that in the local infection and control groups (P<0.05), and the local infection group had higher serum level of IL-6 than the control group (P<0.05). There was no significant difference in the serum IL-8 level among the three groups. According to the ROC curve, when the cut-off value of serum IL-6 was 32 pg/mL, the sensitivity, specificity and accuracy of serum IL-6 for the diagnosis of neonatal sepsis were 87.8%, 79.6% and 81.6% respectively; when the cut-off value of serum IL-8 was 54 pg/mL, the sensitivity, specificity and accuracy of serum IL-6 for the diagnosis of neonatal sepsis were 77.6%, 63.8% and 67.2% respectively. With the combination of serum IL-6 and IL-8 levels, the sensitivity, specificity and accuracy for the diagnosis of neonatal sepsis were 71.4%, 86.2% and 82.6% respectively.
CONCLUSIONS: IL-6 and IL-8 participate in the inflammatory response and the serum levels of both vary with the severity of infection. The diagnostic value of IL-6 for neonatal sepsis is higher than IL-8. The combined detection of serum levels IL-6 and IL-8 may increase the accuracy of diagnosis of neonatal sepsis.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26695671

Source DB:  PubMed          Journal:  Zhongguo Dang Dai Er Ke Za Zhi        ISSN: 1008-8830


  5 in total

1.  A meta-analysis of interleukin-6 as a valid and accurate index in diagnosing early neonatal sepsis.

Authors:  Bo Sun; Lian-Fang Liang; Jie Li; Dan Yang; Xiao-Bing Zhao; Ke-Gang Zhang
Journal:  Int Wound J       Date:  2019-02-07       Impact factor: 3.315

2.  [A pilot study of plasma interleukin-6 and interleukin-27 in differential diagnosis of acute respiratory distress syndrome and neonatal respiratory distress syndrome in preterm infants].

Authors:  Chan Liu; Yu He; Qing Ai; Yuan Shi
Journal:  Zhongguo Dang Dai Er Ke Za Zhi       Date:  2022-04-15

3.  The value of interleukin-6 (IL-6) within 6 hours after birth in the prompt diagnosis of early-onset neonatal sepsis.

Authors:  Chunmei Liu; Chengzhi Fang; Qi He; Lili Xie
Journal:  Transl Pediatr       Date:  2020-10

4.  C-reactive protein for diagnosing late-onset infection in newborn infants.

Authors:  Jennifer Valeska Elli Brown; Nicholas Meader; Jemma Cleminson; William McGuire
Journal:  Cochrane Database Syst Rev       Date:  2019-01-14

5.  Serum Interleukin-8 in Patients with Different Origin of Intra-Abdominal Infections in Perioperative Period.

Authors:  Artem Riga; Valeriy Boyko; Yuriy Grirorov
Journal:  Med Sci (Basel)       Date:  2019-09-08
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.