Literature DB >> 26695335

SPR detection of cardiac troponin T for acute myocardial infarction.

Maria Pawula1, Zeynep Altintas1, Ibtisam E Tothill2.   

Abstract

A surface plasmon resonance (SPR) sensor developed for the rapid, sensitive and specific detection of cardiac troponin T (cTnT) in serum samples is reported in this work. An extensive optimisation of assay parameters was conducted to achieve optimal detection strategy. Both direct and sandwich immunoassay formats were investigated and optimised. The response obtained was enhanced further by the use of gold nanoparticles (AuNPs) conjugated to the anti-cTnT detection antibody. A regeneration method was developed to enable the reuse of the SPR sensor for multiple sample application. The SPR immunosensor showed good reproducibility for cTnT detection in the concentration range of 25-1000 ng mL(-1) and 5-400 ng mL(-1) for the direct and sandwich assays in buffer, respectively. The linear regression analysis was performed and R(2) value was found as 0.99 for both assays. In order to optimise the sensor for serum analysis, nonspecific binding of serum proteins was reduced through the use of additives in the dilution buffer. To achieve greater sensitivity, the performance of the cTnT immunosensor sandwich assay in human serum was evaluated using non-modified and AuNP modified detector antibodies. A detection limit (LOD) for the immunosensor in 50% serum was assessed as 5 ng mL(-1) cTnT for the standard sandwich assay and 0.5 ng mL(-1) cTnT when using AuNP conjugated detector antibodies with a linear dynamic range of 0.5-40 ng mL(-1). The dissociation constant was found as 3.28 × 10(-9) M using Langmuir binding model which indicates high affinity between cTnT and its antibody. The proposed SPR immunosensor has a promising potential to be developed for point-of-care testing for the early diagnosis of acute myocardial infarction (AMI). This method can also be used for the rapid detection of biomarkers in central nervous system diseases.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Acute myocardial infarction; Cardiac troponin T; Early diagnosis; Immunosensor; SPR

Mesh:

Substances:

Year:  2015        PMID: 26695335     DOI: 10.1016/j.talanta.2015.06.006

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  12 in total

1.  An electrochemical troponin T aptasensor based on the use of a macroporous gold nanostructure.

Authors:  Masoud Negahdary; Mostafa Behjati-Ardakani; Hossein Heli
Journal:  Mikrochim Acta       Date:  2019-05-27       Impact factor: 5.833

Review 2.  Applications of Graphene Quantum Dots in Biomedical Sensors.

Authors:  Bhargav D Mansuriya; Zeynep Altintas
Journal:  Sensors (Basel)       Date:  2020-02-16       Impact factor: 3.576

Review 3.  Nanoparticles in the diagnosis and treatment of vascular aging and related diseases.

Authors:  Hui Xu; Shuang Li; You-Shuo Liu
Journal:  Signal Transduct Target Ther       Date:  2022-07-11

4.  Surface Plasmon Resonance Immunosensor with Antibody-Functionalized Magnetoplasmonic Nanoparticles for Ultrasensitive Quantification of the CD5 Biomarker.

Authors:  Asta Kausaite-Minkstimiene; Anton Popov; Almira Ramanaviciene
Journal:  ACS Appl Mater Interfaces       Date:  2022-05-02       Impact factor: 10.383

5.  High-throughput immunosensor chip coupled with a fluorescent DNA dendrimer for ultrasensitive detection of cardiac troponin T.

Authors:  Ruike Wang; Chen Zong; Gairu Li; Junhong Wang; Tiantian Kong; Fei Li; Junmin Chang
Journal:  RSC Adv       Date:  2021-08-13       Impact factor: 3.361

6.  Cardioprotective effect of Notch signaling on the development of myocardial infarction complicated by diabetes mellitus.

Authors:  Fang Wu; Bo Yu; Xu Zhang; Yuelan Zhang
Journal:  Exp Ther Med       Date:  2017-08-16       Impact factor: 2.447

7.  Nanoparticle Enhanced Antibody and DNA Biosensors for Sensitive Detection of Salmonella.

Authors:  Sumeyra Savas; Aylin Ersoy; Yakup Gulmez; Selcuk Kilic; Belkis Levent; Zeynep Altintas
Journal:  Materials (Basel)       Date:  2018-08-27       Impact factor: 3.623

8.  Graphene FET Sensors for Alzheimer's Disease Protein Biomarker Clusterin Detection.

Authors:  Theodore Bungon; Carrie Haslam; Samar Damiati; Benjamin O'Driscoll; Toby Whitley; Paul Davey; Giuliano Siligardi; Jerome Charmet; Shakil A Awan
Journal:  Front Mol Biosci       Date:  2021-03-26

9.  Covalently grafting first-generation PAMAM dendrimers onto MXenes with self-adsorbed AuNPs for use as a functional nanoplatform for highly sensitive electrochemical biosensing of cTnT.

Authors:  Xin Liu; Yong Qiu; Deming Jiang; Fengheng Li; Ying Gan; Yuxuan Zhu; Yuxiang Pan; Hao Wan; Ping Wang
Journal:  Microsyst Nanoeng       Date:  2022-03-30       Impact factor: 7.127

Review 10.  The role of antibody-based troponin detection in cardiovascular disease: A critical assessment.

Authors:  Hui Ma; Arabelle Cassedy; Richard O'Kennedy
Journal:  J Immunol Methods       Date:  2021-07-28       Impact factor: 2.303

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.