Literature DB >> 26695325

Automated determination of nitrate plus nitrite in aqueous samples with flow injection analysis using vanadium (III) chloride as reductant.

Shu Wang1, Kunning Lin1, Nengwang Chen1, Dongxing Yuan1, Jian Ma2.   

Abstract

Determination of nitrate in aqueous samples is an important analytical objective for environmental monitoring and assessment. Here we report the first automatic flow injection analysis (FIA) of nitrate (plus nitrite) using VCl3 as reductant instead of the well-known but toxic cadmium column for reducing nitrate to nitrite. The reduced nitrate plus the nitrite originally present in the sample react with the Griess reagent (sulfanilamide and N-1-naphthylethylenediamine dihydrochloride) under acidic condition. The resulting pink azo dye can be detected at 540 nm. The Griess reagent and VCl3 are used as a single mixed reagent solution to simplify the system. The various parameters of the FIA procedure including reagent composition, temperature, volume of the injection loop, and flow rate were carefully investigated and optimized via univariate experimental design. Under the optimized conditions, the linear range and detection limit of this method are 0-100 µM (R(2)=0.9995) and 0.1 µM, respectively. The targeted analytical range can be easily extended to higher concentrations by selecting alternative detection wavelengths or increasing flow rate. The FIA system provides a sample throughput of 20 h(-1), which is much higher than that of previously reported manual methods based on the same chemistry. National reference solutions and different kinds of aqueous samples were analyzed with our method as well as the cadmium column reduction method. The results from our method agree well with both the certified value and the results from the cadmium column reduction method (no significant difference with P=0.95). The spiked recovery varies from 89% to 108% for samples with different matrices, showing insignificant matrix interference in this method.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Aqueous sample; Flow injection analysis; Griess reaction; Nitrate; Nitrite; Vanadium (III) chloride reduction

Year:  2015        PMID: 26695325     DOI: 10.1016/j.talanta.2015.06.031

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  5 in total

1.  Improvement of On-Site Sensor for Simultaneous Determination of Phosphate, Silicic Acid, Nitrate plus Nitrite in Seawater.

Authors:  Mahmoud Fatehy Altahan; Mario Esposito; Eric P Achterberg
Journal:  Sensors (Basel)       Date:  2022-05-03       Impact factor: 3.847

Review 2.  Autonomous and In Situ Ocean Environmental Monitoring on Optofluidic Platform.

Authors:  Fang Wang; Jiaomeng Zhu; Longfei Chen; Yunfeng Zuo; Xuejia Hu; Yi Yang
Journal:  Micromachines (Basel)       Date:  2020-01-08       Impact factor: 2.891

Review 3.  A Review of Methods to Determine Viability, Vitality, and Metabolic Rates in Microbiology.

Authors:  Olivier Braissant; Monika Astasov-Frauenhoffer; Tuomas Waltimo; Gernot Bonkat
Journal:  Front Microbiol       Date:  2020-11-17       Impact factor: 5.640

4.  Improving Sustainability of the Griess Reaction by Reagent Stabilization on PDMS Membranes and ZnNPs as Reductor of Nitrates: Application to Different Water Samples.

Authors:  Lusine Hakobyan; Belén Monforte-Gómez; Yolanda Moliner-Martínez; Carmen Molins-Legua; Pilar Campíns-Falcó
Journal:  Polymers (Basel)       Date:  2022-01-24       Impact factor: 4.329

5.  Sensitive and selective colorimetric nitrite ion assay using silver nanoparticles easily synthesized and stabilized by AHNDMS and functionalized with PABA.

Authors:  Mohammed Hassan Ibrahim; Zhonghua Xue; Hassan Idris Abdu; Mahgoub Ibrahim Shinger; Ahmed Mahmoud Idris; Murtada Mohamed Edris; Duoliang Shan; Xiaoquan Lu
Journal:  Nanoscale Adv       Date:  2018-12-24
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.