Qi Wan1, Shiyang Wang2, Jiaxuan Zhou1, Qiao Zou1, Yingshi Deng1, Shouyang Wang1, Xiaoying Zheng3, Xinchun Li1. 1. Department of Radiology, First Affiliated Hospital of Guangzhou Medical University, Guangzhou, Guangdong, China. 2. Department of Radiology, Medical Center of University of Chicago, Chicago, Illinois, USA. 3. 75660 Unit, Xiangshan District, Guilin, Guangxi, China.
Abstract
PURPOSE: To investigate the potential of diffusion tensor imaging (DTI) and T2 measurements in the evaluation of radiation-induced peripheral nerve injury (RIPNI). MATERIALS AND METHODS: RIPNI was produced in a randomly selected side of sciatic nerve in each of 21 rabbits while the contralateral side served as the control. The limb function and MR parameters were evaluated over a 4-month period. Fractional anisotropy (FA), axial diffusivity (λ∥ ), radial diffusivity (λ⊥ ) and T2 values were obtained using 3T MR for quantitative analysis. Two animals were randomly killed for histological evaluation at each timepoint. RESULTS: The T2 value of irradiated nerve increased at 1 day (63.95 ± 15.60, P = 0.012) and was restored at 1 month (52.34 ± 5.38, P = 0.105). It increased progressively at 2 to 4 months (60.39 ± 10.60, 66.96 ± 6.08, 75.51 ± 7.39, all P < 0.01). λ⊥ significantly increased at 1 day (0.82 ± 0.44, P = 0.046) and slightly decreased at 1 month (0.61 ± 0.17, P < 0.001). It increased gradually from 2 to 3 months (0.84 ± 0.29, 1.13 ± 0.33, both P < 0.001) followed by a decline at 4 months (0.83 ± 0.17, P < 0.001). FA was statistically lower than the contralateral sides at 1 to 4 months (0.72 ± 0.08, 0.60 ± 0.12, 0.51 ± 0.11, 0.62 ± 0.06, all P < 0.01). Changes in FA and λ⊥ correlated well with the functional and pathological changes in irradiated nerve. CONCLUSION: DTI may be a more sensitive and accurate method to evaluate RIPNI compared with T2 measurements. FA and λ⊥ are promising quantitative indices in monitoring RIPNI. J. Magn. Reson. Imaging 2016;43:1492-1499.
PURPOSE: To investigate the potential of diffusion tensor imaging (DTI) and T2 measurements in the evaluation of radiation-induced peripheral nerve injury (RIPNI). MATERIALS AND METHODS: RIPNI was produced in a randomly selected side of sciatic nerve in each of 21 rabbits while the contralateral side served as the control. The limb function and MR parameters were evaluated over a 4-month period. Fractional anisotropy (FA), axial diffusivity (λ∥ ), radial diffusivity (λ⊥ ) and T2 values were obtained using 3T MR for quantitative analysis. Two animals were randomly killed for histological evaluation at each timepoint. RESULTS: The T2 value of irradiated nerve increased at 1 day (63.95 ± 15.60, P = 0.012) and was restored at 1 month (52.34 ± 5.38, P = 0.105). It increased progressively at 2 to 4 months (60.39 ± 10.60, 66.96 ± 6.08, 75.51 ± 7.39, all P < 0.01). λ⊥ significantly increased at 1 day (0.82 ± 0.44, P = 0.046) and slightly decreased at 1 month (0.61 ± 0.17, P < 0.001). It increased gradually from 2 to 3 months (0.84 ± 0.29, 1.13 ± 0.33, both P < 0.001) followed by a decline at 4 months (0.83 ± 0.17, P < 0.001). FA was statistically lower than the contralateral sides at 1 to 4 months (0.72 ± 0.08, 0.60 ± 0.12, 0.51 ± 0.11, 0.62 ± 0.06, all P < 0.01). Changes in FA and λ⊥ correlated well with the functional and pathological changes in irradiated nerve. CONCLUSION: DTI may be a more sensitive and accurate method to evaluate RIPNI compared with T2 measurements. FA and λ⊥ are promising quantitative indices in monitoring RIPNI. J. Magn. Reson. Imaging 2016;43:1492-1499.
Authors: Annina B Schmid; Jon Campbell; Samuel A Hurley; Saad Jbabdi; Jesper L Andersson; Mark Jenkinson; Neal K Bangerter; David L Bennett; Irene Tracey; Robert Frost; Stuart Clare Journal: Invest Radiol Date: 2018-12 Impact factor: 6.016
Authors: Tina Jeon; Emil S Vutescu; Eliana B Saltzman; Jordan C Villa; Scott W Wolfe; Steve K Lee; Joseph H Feinberg; Sarah L Pownder; Jonathan P Dyke; Darryl B Sneag Journal: Eur Radiol Exp Date: 2018-08-08