Literature DB >> 2669130

Current status of immunoscintigraphy in the detection of thrombosis and thromboembolism.

P D Koblik1, G L De Nardo, H J Berger.   

Abstract

This review describes the use of monoclonal antibodies (MoAbs) for immunoscintigraphic detection of thrombosis and thromboembolism. Two major groups of MoAbs have been tested: Antibodies directed against platelets and antibodies directed against fibrin. Several antiplatelet antibodies have been developed that are directed against either the platelet membrane glycoprotein complex, IIb/IIIa, which binds fibrinogen, or against two different proteins, alpha granule membrane protein GMP-140 and thrombospondin (TSP) that are expressed during platelet activation. Platelets labeled with radioactive antibody or antibody fragments have characteristics similar to platelets labeled in vitro with lipophilic complexes. Studies in animal models indicate that antiplatelet antibody and antiactivated platelet factor antibody imaging have a high sensitivity for clots less than 24 hours old and that images can be positive as early as one to two hours after antibody administration. A limited number of antiplatelet antibody studies have been performed in patients. This technique appears to yield accurate results provided that active platelet deposition is occurring at the time of the study. Several antifibrin MoAbs, specific for fibrin monomers, have been developed. Compared with antiplatelet antibodies, antifibrin antibodies and antibody fragments appear to be capable of detecting older experimental clots (up to five days old). Images in experimental thrombosis models are routinely positive within two hours of antibody administration. Recently reported clinical trials indicate a high sensitivity in all anatomic locations within the extremities whether or not patients were receiving heparin.

Entities:  

Mesh:

Substances:

Year:  1989        PMID: 2669130     DOI: 10.1016/s0001-2998(89)80015-7

Source DB:  PubMed          Journal:  Semin Nucl Med        ISSN: 0001-2998            Impact factor:   4.446


  3 in total

Review 1.  Does immunoscintigraphy serve clinical needs effectively? Is there a future for radioimmunotherapy?

Authors:  J F Chatal; P Peltier; M Bardiès; A Chétanneau; P Thedrez; A Faivre-Chauvet; J F Gestin
Journal:  Eur J Nucl Med       Date:  1992

2.  [131I]FIAU labeling of genetically transduced, tumor-reactive lymphocytes: cell-level dosimetry and dose-dependent toxicity.

Authors:  Pat Zanzonico; Guenther Koehne; Humilidad F Gallardo; Mikhail Doubrovin; Ekaterina Doubrovina; Ronald Finn; Ronald G Blasberg; Isabelle Riviere; Richard J O'Reilly; Michel Sadelain; Steven M Larson
Journal:  Eur J Nucl Med Mol Imaging       Date:  2006-04-11       Impact factor: 9.236

3.  Safety, pharmacokinetic and dosimetry evaluation of the proposed thrombus imaging agent 99mTc-DI-DD-3B6/22-80B3 Fab'.

Authors:  David J Macfarlane; Richard C Smart; Wendy W Tsui; Michael Gerometta; Paul R Eisenberg; Andrew M Scott
Journal:  Eur J Nucl Med Mol Imaging       Date:  2006-03-10       Impact factor: 9.236

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.