Literature DB >> 26688537

Accuracy of Xpert(®) MTB/RIF assay compared with AdvanSure™ TB/NTM real-time PCR using bronchoscopy specimens.

Y Ko1, H-K Lee2, Y S Lee3, M-Y Kim2, J H Shin4, E-J Shim5, S Y Park6, E K Mo6, Y B Park6.   

Abstract

BACKGROUND: The performance of Xpert(®) MTB/RIF assay, an automated nucleic acid amplification test (NAAT) that was developed for the detection of tuberculosis (TB), has been evaluated in various clinical settings. However, few studies have compared Xpert with other NAATs, especially its performance using lower respiratory tract specimens (LRTS).
OBJECTIVE: To compare the practical diagnostic performance of the Xpert assay with that of the AdvanSure™ TB/NTM RT-PCR kit in the detection of pulmonary TB (PTB), using LRTS obtained through bronchoscopy.
RESULTS: Of 249 patients included, 105 had culture-confirmed PTB. Using culture as reference, the overall sensitivity of Xpert and AdvanSure was respectively 92.4% and 83.8%. When acid-fast bacilli smear results were taken into consideration, the sensitivity of Xpert for smear-positive and smear-negative LRTS was respectively 100% and 88.9%, while that of the AdvanSure was 100% and 76.4%. Xpert showed better results than AdvanSure in terms of sensitivity in smear-negative LRTS (P = 0.012), but no difference in smear-positive LRTS.
CONCLUSIONS: Xpert may be advantageous in the detection of PTB using LRTS, particularly in low microbiological burden settings.

Entities:  

Mesh:

Year:  2016        PMID: 26688537     DOI: 10.5588/ijtld.15.0227

Source DB:  PubMed          Journal:  Int J Tuberc Lung Dis        ISSN: 1027-3719            Impact factor:   2.373


  6 in total

1.  Xpert MTB/RIF and Xpert MTB/RIF Ultra for pulmonary tuberculosis and rifampicin resistance in adults.

Authors:  David J Horne; Mikashmi Kohli; Jerry S Zifodya; Ian Schiller; Nandini Dendukuri; Deanna Tollefson; Samuel G Schumacher; Eleanor A Ochodo; Madhukar Pai; Karen R Steingart
Journal:  Cochrane Database Syst Rev       Date:  2019-06-07

Review 2.  Accuracy of the Bronchoalveolar Lavage Enzyme-Linked Immunospot Assay for the Diagnosis of Pulmonary Tuberculosis: A Meta-analysis.

Authors:  Caishuang Pang; Yanqiu Wu; Chun Wan; Konglong Shen; Yuzhu Hu; Ting Yang; Yongchun Shen; Fuqiang Wen
Journal:  Medicine (Baltimore)       Date:  2016-03       Impact factor: 1.889

3.  Correlation of microbiological yield with radiographic activity on chest computed tomography in cases of suspected pulmonary tuberculosis.

Authors:  Yousang Ko; Ho Young Lee; Yong Bum Park; Su Jin Hong; Jeong Hwan Shin; Seok Jin Choi; Changhwan Kim; So Young Park; Jin Young Jeong
Journal:  PLoS One       Date:  2018-08-09       Impact factor: 3.240

4.  Comparative Evaluation of the Loop-Mediated Isothermal Amplification Assay for Detecting Pulmonary Tuberculosis.

Authors:  Chang Ki Kim; Eun A Cho; Dong Mi Shin; Sung Won Choi; So Youn Shin
Journal:  Ann Lab Med       Date:  2018-03       Impact factor: 3.464

5.  Performance of the Xpert® MTB/RIF assay in the rapid diagnosis of tracheobronchial tuberculosis using bronchial washing fluid.

Authors:  Yan-Hua Song; Qiang Li; Li-Ping Ma; Rong-Mei Liu; Guang-Lu Jiang; Qi Li; Meng-Qiu Gao
Journal:  J Int Med Res       Date:  2020-10       Impact factor: 1.671

6.  Head-to-Head Comparison between Xpert MTB/RIF Assay and Real-Time Polymerase Chain Reaction Assay Using Bronchial Washing Specimens for Tuberculosis Diagnosis.

Authors:  Eunjeong Son; Jinook Jang; Taehwa Kim; Jin Ho Jang; Jae Heun Chung; Hee Yun Seol; Hye Ju Yeo; Seong Hoon Yoon; Seung Eun Lee; Woo Hyun Cho; Yun Seong Kim; Doosoo Jeon
Journal:  Tuberc Respir Dis (Seoul)       Date:  2021-11-02
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.