Literature DB >> 26687976

Inter-laboratory evaluation of the performance parameters of a Lateral Flow Test device for the detection of Bluetongue virus-specific antibodies.

Jean-Baptiste Hanon1, Valerie Vandenberge2, Matthias Deruelle2, Ilse De Leeuw3, Kris De Clercq3, Steven Van Borm4, Frank Koenen2, Lihong Liu5, Bernd Hoffmann6, Carrie Anne Batten7, Stéphan Zientara8, Emmanuel Breard8, Yves Van der Stede9.   

Abstract

Bluetongue (BT) is a viral vector-borne disease affecting domestic and wild ruminants worldwide. In this study, a commercial rapid immuno-chromatographic method or Lateral Flow Test (LFT) device, for the detection of BT virus-specific antibodies in animal serum, was evaluated in an international inter-laboratory proficiency test. The evaluation was done with sera samples of variable background (ruminant species, serotype, field samples, experimental infections, vaccinated animals). The diagnostic sensitivity was 100% (95% C.I. [90.5-100]) and the diagnostic specificity was 95.2% (95% C.I. [76.2-99.9]). The repeatability (accordance) and reproducibility (concordance) were 100% for seropositive samples but were lower for two of the seronegative samples (45% and 89% respectively). The analytical sensitivity, evaluated by testing positive sera at increasing dilutions was better for the BT LFT compared to some commercial ELISAs. Seroconversion of an infected sheep was detected at 4 days post infection. Analytical specificity was impaired by cross-reactions observed with some of the samples seropositive for Epizootic Haemorrhagic Disease Virus (EHDV). The agreement (Cohen's kappa) between the LFT and a commercial BT competitive ELISA was 0.79 (95% CI [0.62-0.95]). Based on these results, it can be concluded that the BT LFT device is a rapid and sensitive first-line serological test that can be used in the field, especially in areas endemic for the disease where there is a lack of diagnostic facilities.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Bluetongue; ELISA; Immuno-chromatographic strip; Lateral Flow Test; Pen-side test; Proficiency test

Mesh:

Substances:

Year:  2015        PMID: 26687976     DOI: 10.1016/j.jviromet.2015.12.001

Source DB:  PubMed          Journal:  J Virol Methods        ISSN: 0166-0934            Impact factor:   2.014


  4 in total

Review 1.  Advanced biosensors for detection of pathogens related to livestock and poultry.

Authors:  Jasmina Vidic; Marisa Manzano; Chung-Ming Chang; Nicole Jaffrezic-Renault
Journal:  Vet Res       Date:  2017-02-21       Impact factor: 3.683

Review 2.  Point-of-Care Diagnostics for Farm Animal Diseases: From Biosensors to Integrated Lab-on-Chip Devices.

Authors:  Georgios Manessis; Athanasios I Gelasakis; Ioannis Bossis
Journal:  Biosensors (Basel)       Date:  2022-06-26

Review 3.  Validation of laboratory tests for infectious diseases in wild mammals: review and recommendations.

Authors:  Beibei Jia; Axel Colling; David E Stallknecht; David Blehert; John Bingham; Beate Crossley; Debbie Eagles; Ian A Gardner
Journal:  J Vet Diagn Invest       Date:  2020-05-29       Impact factor: 1.279

4.  Detection of Paratuberculosis in Dairy Herds by Analyzing the Scent of Feces, Alveolar Gas, and Stable Air.

Authors:  Michael Weber; Peter Gierschner; Anne Klassen; Elisa Kasbohm; Jochen K Schubert; Wolfram Miekisch; Petra Reinhold; Heike Köhler
Journal:  Molecules       Date:  2021-05-11       Impact factor: 4.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.