Assessment of calibration methods on impedance pneumography accuracy.

Marcel Młyńczak, Wiktor Niewiadomski, Marek Żyliński, Gerard Cybulski.   

Abstract

The aim was to assess accuracy of tidal volumes (TV) calculated by impedance pneumography (IP), reproducibility of calibration coefficients (CC) between IP and pneumotachometry (PNT), and their relationship with body posture, breathing rate and depth. Fourteen students performed three sessions of 18 series: normal and deep breathing at 6, 10, 15 breaths/min rates, while supine, sitting and standing; 18 CC were calculated for every session. Session 2 was performed 2 months after session 1, session 3 1-3 days after session 2. TV were calculated using full or limited set of CC from current session, in case of sessions 2 and 3 also using CC from session 1 and 2, respectively. When using full set of CC from current session, IP underestimated TV by -3.2%. Using CC from session 2 for session 3 measurements caused decrease of relative difference: -3.9%, from session 1 for session 2: -5.3%; for limited set of CC: -5.0%. The body posture had significant effect on CC. The highest accuracy was obtained when all factors influencing CC were considered. The application of CC related only to body posture may result in shortening of calibration and moderate accuracy loss. Using CC from previous session compromises accuracy moderately.

Mesh:

Year:  2016        PMID: 26684348     DOI: 10.1515/bmt-2015-0125

Source DB:  PubMed          Journal:  Biomed Tech (Berl)        ISSN: 0013-5585            Impact factor:   1.411


  4 in total

1.  Towards Estimation of Tidal Volume and Respiratory Timings via Wearable-Patch-Based Impedance Pneumography in Ambulatory Settings.

Authors:  John A Berkebile; Samer A Mabrouk; Venu G Ganti; Adith V Srivatsa; Jesus Antonio Sanchez-Perez; Omer T Inan
Journal:  IEEE Trans Biomed Eng       Date:  2022-05-19       Impact factor: 4.756

2.  Discovery of Causal Paths in Cardiorespiratory Parameters: A Time-Independent Approach in Elite Athletes.

Authors:  Marcel Młyńczak; Hubert Krysztofiak
Journal:  Front Physiol       Date:  2018-10-30       Impact factor: 4.566

3.  A Wearable Multimodal Sensing System for Tracking Changes in Pulmonary Fluid Status, Lung Sounds, and Respiratory Markers.

Authors:  Jesus Antonio Sanchez-Perez; John A Berkebile; Brandi N Nevius; Goktug C Ozmen; Christopher J Nichols; Venu G Ganti; Samer A Mabrouk; Gari D Clifford; Rishikesan Kamaleswaran; David W Wright; Omer T Inan
Journal:  Sensors (Basel)       Date:  2022-02-02       Impact factor: 3.576

4.  Simple Wireless Impedance Pneumography System for Unobtrusive Sensing of Respiration.

Authors:  Pablo Aqueveque; Britam Gómez; Emyrna Monsalve; Enrique Germany; Paulina Ortega-Bastidas; Sebastián Dubo; Esteban J Pino
Journal:  Sensors (Basel)       Date:  2020-09-14       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.