Martin Schmidt1, Uwe Dorwarth2, Dietrich Andresen3, Johannes Brachmann4, Karlheinz Kuck5, Malte Kuniss6, Stephan Willems7, Thomas Deneke8, Jürgen Tebbenjohanns9, Jin-Hong Gerds-Li10, Stefan Spitzer11, Jochen Senges12, Matthias Hochadel12, Ellen Hoffmann2. 1. Department of Cardiology, Klinikum Bogenhausen, Munich, Germany. Electronic address: mschmidtco@arcor.de. 2. Department of Cardiology, Klinikum Bogenhausen, Munich, Germany. 3. Department of Cardiology, Vivantes Klinikum am Urban, Berlin, Germany. 4. Department of Cardiology, Klinikum Coburg, Coburg, Germany. 5. Department of Cardiology, Asklepios Klinik St. Georg, Hamburg, Germany. 6. Department of Cardiology, Kerckhoff-Klinik, Bad Nauheim, Germany. 7. Department of Cardiology, Universitäres Herzzentrum Hamburg, Hamburg, Germany. 8. Department of Cardiology, Herz-und Gefäß-Klinik, Bad Neustadt, Germany. 9. Department of Cardiology, HELIOS Klinikum Hildesheim, Hildesheim, Germany. 10. Deutsches Herzzentrum Berlin, Berlin, Germany. 11. Praxisklinik Herz und Gefäße, Dresden, Germany. 12. Stiftung Institut für Herzinfarktforschung, IHF, Ludwigshafen, Germany.
Abstract
BACKGROUND: Although radiofrequency (RF) ablation has long been the standard of care for atrial fibrillation (AF) ablation, cryoballoon technology has emerged as a feasible approach with promising results. Prospective multicenter registry data referring to both ablation technologies in AF ablation are lacking so far. OBJECTIVE: The purpose of this study was to report data from the German ablation registry with respect to efficacy and safety in pulmonary vein ablation with different energy sources for paroxysmal AF after 1-year follow-up. METHODS: A total of 2306 patients with symptomatic paroxysmal AF from the German ablation registry were included in this analysis. The cohort was divided into two groups according to the ablation energy source used: cryoballoon and RF ablation. MACCE was defined as a combination of death, myocardial infarction, or stroke. RESULTS: AF recurrence rate after a single ablation procedure at 1 year follow-up was not significantly different between the two groups (45.8% after cryoablation and 45.4% after RF ablation, P = .87). Also, the rate of patients without AF recurrence and free of antiarrhythmic drug at 12-month follow-up was similar (cryoablation 44.2% and RF 41.4%, P = .25). MACCE occurred with an incidence of 0.7% within 500 days after cryoablation and 1.4% after RF ablation (P = .30). Persistent phrenic nerve palsy was more common after cryoablation compared to RF ablation (1.1% vs. 0.3%, P <.05). CONCLUSION: AF recurrence rate at 1-year follow-up was similar in RF ablation compared to cryoablation, whereas the spectrum and relevance of complications were significantly different between the two ablation methods. This finding might influence the choice of ablation method offered to the individual paroxysmal AF patient.
BACKGROUND: Although radiofrequency (RF) ablation has long been the standard of care for atrial fibrillation (AF) ablation, cryoballoon technology has emerged as a feasible approach with promising results. Prospective multicenter registry data referring to both ablation technologies in AF ablation are lacking so far. OBJECTIVE: The purpose of this study was to report data from the German ablation registry with respect to efficacy and safety in pulmonary vein ablation with different energy sources for paroxysmal AF after 1-year follow-up. METHODS: A total of 2306 patients with symptomatic paroxysmal AF from the German ablation registry were included in this analysis. The cohort was divided into two groups according to the ablation energy source used: cryoballoon and RF ablation. MACCE was defined as a combination of death, myocardial infarction, or stroke. RESULTS:AF recurrence rate after a single ablation procedure at 1 year follow-up was not significantly different between the two groups (45.8% after cryoablation and 45.4% after RF ablation, P = .87). Also, the rate of patients without AF recurrence and free of antiarrhythmic drug at 12-month follow-up was similar (cryoablation 44.2% and RF 41.4%, P = .25). MACCE occurred with an incidence of 0.7% within 500 days after cryoablation and 1.4% after RF ablation (P = .30). Persistent phrenic nerve palsy was more common after cryoablation compared to RF ablation (1.1% vs. 0.3%, P <.05). CONCLUSION:AF recurrence rate at 1-year follow-up was similar in RF ablation compared to cryoablation, whereas the spectrum and relevance of complications were significantly different between the two ablation methods. This finding might influence the choice of ablation method offered to the individual paroxysmal AFpatient.
Authors: Hugh Calkins; Gerhard Hindricks; Riccardo Cappato; Young-Hoon Kim; Eduardo B Saad; Luis Aguinaga; Joseph G Akar; Vinay Badhwar; Josep Brugada; John Camm; Peng-Sheng Chen; Shih-Ann Chen; Mina K Chung; Jens Cosedis Nielsen; Anne B Curtis; D Wyn Davies; John D Day; André d'Avila; N M S Natasja de Groot; Luigi Di Biase; Mattias Duytschaever; James R Edgerton; Kenneth A Ellenbogen; Patrick T Ellinor; Sabine Ernst; Guilherme Fenelon; Edward P Gerstenfeld; David E Haines; Michel Haissaguerre; Robert H Helm; Elaine Hylek; Warren M Jackman; Jose Jalife; Jonathan M Kalman; Josef Kautzner; Hans Kottkamp; Karl Heinz Kuck; Koichiro Kumagai; Richard Lee; Thorsten Lewalter; Bruce D Lindsay; Laurent Macle; Moussa Mansour; Francis E Marchlinski; Gregory F Michaud; Hiroshi Nakagawa; Andrea Natale; Stanley Nattel; Ken Okumura; Douglas Packer; Evgeny Pokushalov; Matthew R Reynolds; Prashanthan Sanders; Mauricio Scanavacca; Richard Schilling; Claudio Tondo; Hsuan-Ming Tsao; Atul Verma; David J Wilber; Teiichi Yamane Journal: Heart Rhythm Date: 2017-05-12 Impact factor: 6.343
Authors: Hugh Calkins; Karl Heinz Kuck; Riccardo Cappato; Josep Brugada; A John Camm; Shih-Ann Chen; Harry J G Crijns; Ralph J Damiano; D Wyn Davies; John DiMarco; James Edgerton; Kenneth Ellenbogen; Michael D Ezekowitz; David E Haines; Michel Haissaguerre; Gerhard Hindricks; Yoshito Iesaka; Warren Jackman; José Jalife; Pierre Jais; Jonathan Kalman; David Keane; Young-Hoon Kim; Paulus Kirchhof; George Klein; Hans Kottkamp; Koichiro Kumagai; Bruce D Lindsay; Moussa Mansour; Francis E Marchlinski; Patrick M McCarthy; J Lluis Mont; Fred Morady; Koonlawee Nademanee; Hiroshi Nakagawa; Andrea Natale; Stanley Nattel; Douglas L Packer; Carlo Pappone; Eric Prystowsky; Antonio Raviele; Vivek Reddy; Jeremy N Ruskin; Richard J Shemin; Hsuan-Ming Tsao; David Wilber Journal: Heart Rhythm Date: 2012-03-01 Impact factor: 6.343
Authors: Hugh Calkins; Gerhard Hindricks; Riccardo Cappato; Young-Hoon Kim; Eduardo B Saad; Luis Aguinaga; Joseph G Akar; Vinay Badhwar; Josep Brugada; John Camm; Peng-Sheng Chen; Shih-Ann Chen; Mina K Chung; Jens Cosedis Nielsen; Anne B Curtis; D Wyn Davies; John D Day; André d'Avila; N M S Natasja de Groot; Luigi Di Biase; Mattias Duytschaever; James R Edgerton; Kenneth A Ellenbogen; Patrick T Ellinor; Sabine Ernst; Guilherme Fenelon; Edward P Gerstenfeld; David E Haines; Michel Haissaguerre; Robert H Helm; Elaine Hylek; Warren M Jackman; Jose Jalife; Jonathan M Kalman; Josef Kautzner; Hans Kottkamp; Karl Heinz Kuck; Koichiro Kumagai; Richard Lee; Thorsten Lewalter; Bruce D Lindsay; Laurent Macle; Moussa Mansour; Francis E Marchlinski; Gregory F Michaud; Hiroshi Nakagawa; Andrea Natale; Stanley Nattel; Ken Okumura; Douglas Packer; Evgeny Pokushalov; Matthew R Reynolds; Prashanthan Sanders; Mauricio Scanavacca; Richard Schilling; Claudio Tondo; Hsuan-Ming Tsao; Atul Verma; David J Wilber; Teiichi Yamane Journal: Europace Date: 2018-01-01 Impact factor: 5.214
Authors: Jesus M Paylos; Aracelis Morales; Luis Azcona; Marisol Paradela; Raquel Yagüe; Fernando Gómez-Guijarro; Lourdes Lacal; R N Clara Ferrero; Octavio Rodríguez Journal: J Atr Fibrillation Date: 2016-04-30