Literature DB >> 26677314

Development of an endoluminal high-intensity ultrasound applicator for image-guided thermal therapy of pancreatic tumors.

Matthew S Adams1, Serena J Scott2, Vasant A Salgaonkar2, Peter D Jones2, Juan C Plata-Camargo3, Graham Sommer4, Chris J Diederich1.   

Abstract

An ultrasound applicator for endoluminal thermal therapy of pancreatic tumors has been introduced and evaluated through acoustic/biothermal simulations and ex vivo experimental investigations. Endoluminal therapeutic ultrasound constitutes a minimally invinvasive conformal therapy and is compatible with ultrasound or MR-based image guidance. The applicator would be placed in the stomach or duodenal lumen, and sonication would be performed through the luminal wall into the tumor, with concurrent water cooling of the wall tissue to prevent its thermal injury. A finite-element (FEM) 3D acoustic and biothermal model was implemented for theoretical analysis of the approach. Parametric studies over transducer geometries and frequencies revealed that operating frequencies within 1-3 MHz maximize penetration depth and lesion volume while sparing damage to the luminal wall. Patient-specific FEM models of pancreatic head tumors were generated and used to assess the feasibility of performing endoluminal ultrasound thermal ablation and hyperthermia of pancreatic tumors. Results indicated over 80% of the volume of small tumors (~2 cm diameter) within 35 mm of the duodenum could be safely ablated in under 30 minutes or elevated to hyperthermic temperatures at steady-state. Approximately 60% of a large tumor (~5 cm diameter) model could be safely ablated by considering multiple positions of the applicator along the length of the duodenum to increase coverage. Prototype applicators containing two 3.2 MHz planar transducers were fabricated and evaluated in ex vivo porcine carcass heating experiments under MR temperature imaging (MRTI) guidance. The applicator was positioned in the stomach adjacent to the pancreas, and sonications were performed for 10 min at 5 W/cm2 applied intensity. MRTI indicated over 40°C temperature rise in pancreatic tissue with heating penetration extending 3 cm from the luminal wall.

Entities:  

Keywords:  MR guided ultrasound; catheter-based ultrasound; endoluminal; pancreatic cancer; thermal modeling; thermal therapy; ultrasound ablation

Year:  2015        PMID: 26677314      PMCID: PMC4677833          DOI: 10.1117/12.2078841

Source DB:  PubMed          Journal:  Proc SPIE Int Soc Opt Eng        ISSN: 0277-786X


  8 in total

1.  Sound field calculation for rectangular sources.

Authors:  K B Ocheltree; L A Frizzel
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1989       Impact factor: 2.725

Review 2.  Systematic review of novel ablative methods in locally advanced pancreatic cancer.

Authors:  Margaret G Keane; Konstantinos Bramis; Stephen P Pereira; Giuseppe K Fusai
Journal:  World J Gastroenterol       Date:  2014-03-07       Impact factor: 5.742

Review 3.  The development and testing of a new temperature-sensitive drug delivery system for the treatment of solid tumors.

Authors:  D Needham; M W Dewhirst
Journal:  Adv Drug Deliv Rev       Date:  2001-12-31       Impact factor: 15.470

4.  Thermal dose determination in cancer therapy.

Authors:  S A Sapareto; W C Dewey
Journal:  Int J Radiat Oncol Biol Phys       Date:  1984-06       Impact factor: 7.038

Review 5.  Today's thermal therapy: not your father's hyperthermia: challenges and opportunities in application of hyperthermia for the 21st century cancer patient.

Authors:  Mark D Hurwitz
Journal:  Am J Clin Oncol       Date:  2010-02       Impact factor: 2.339

6.  Hepatic bipolar radiofrequency ablation creates coagulation zones close to blood vessels: a finite element study.

Authors:  D Haemmerich; A W Wright; D M Mahvi; F T Lee; J G Webster
Journal:  Med Biol Eng Comput       Date:  2003-05       Impact factor: 2.602

Review 7.  Advanced pancreatic carcinoma: current treatment and future challenges.

Authors:  Anastasios Stathis; Malcolm J Moore
Journal:  Nat Rev Clin Oncol       Date:  2010-01-26       Impact factor: 66.675

Review 8.  High-intensity focused ultrasound treatment for advanced pancreatic cancer.

Authors:  Yufeng Zhou
Journal:  Gastroenterol Res Pract       Date:  2014-06-26       Impact factor: 2.260

  8 in total
  1 in total

1.  Deployable ultrasound applicators for endoluminal delivery of volumetric hyperthermia.

Authors:  Muhammad Zubair; Matthew S Adams; Chris J Diederich
Journal:  Int J Hyperthermia       Date:  2021-08-10       Impact factor: 3.914

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.