Literature DB >> 26676176

Instantaneous Decrease in Left Ventricular Afterload during Transcatheter Aortic Valve Implantation Results in Immediate Changes in Left Ventricular Strain.

Amy Swan1, Roshan Prakash1, Derek P Chew1,2, Rebecca Perry1,2, Ajay Sinhal1,2, Joseph B Selvanayagam1,2,3, Majo X Joseph1,2.   

Abstract

Severe aortic stenosis causes chronic increased afterload on the left ventricle (LV) resulting in myocardial hypertrophy and ultimately dysfunction if left untreated. Transcatheter aortic valve implantation (TAVI) immediately decreases the afterload on the LV by reducing the pressure gradient through the aortic valve. In our study, we aim to evaluate immediate changes in LV mechanics using intra-procedural transesophageal echocardiography (TEE) to assess circumferential and radial strain via speckle tracking. Intra-operative TEE was performed during TAVI for 53 patients (mean age 84 ± 8 years). Two-dimensional images in the transgastric view were acquired at the level of the papillary muscle. Circumferential and radial strain was calculated using speckle tracking with Philips Qlab software. Global LV afterload was measured by calculating valvulo-arterial impedance (Zva). Immediately post-TAVI, there was a change in both radial strain rate (Pre: 0.73 ± 0.04 vs. Post: 0.88 ± 0.04 per second, P < 0.001) and circumferential strain rate (-0.53 ± 0.04 (pre) vs. -0.74 ± 0.04 (post) per second, P < 0.001). There was also an immediate improvement in circumferential global strain parameters (-14.5 ± 5% (pre) vs. -16.0 ± 4.7% (post), P < 0.05), whereas there was no significant change seen in global radial strain (15.6 ± 0.8% (pre) vs. 15.2 ± 0.9% (post), P = 0.69). No significant change was seen in LV ejection fraction (51.5 ± 14.2% (pre) vs. 52.1 ± 14.0% (post), P = 0.77). Speckle tracking using TEE images is feasible and identifies significant improvements in LV strain and strain rate immediately following TAVI that is not detected by conventional measure of LV function.
© 2015, Wiley Periodicals, Inc.

Entities:  

Keywords:  aortic stenosis; strain; transesophageal echocardiography

Mesh:

Year:  2015        PMID: 26676176     DOI: 10.1111/echo.13153

Source DB:  PubMed          Journal:  Echocardiography        ISSN: 0742-2822            Impact factor:   1.724


  2 in total

1.  Global longitudinal strain is associated with better outcomes in transcatheter aortic valve replacement.

Authors:  Fadi Al-Rashid; Matthias Totzeck; Nadine Saur; Rolf Alexander Jánosi; Alexander Lind; Amir A Mahabadi; Tienush Rassaf; Raluca-Ileana Mincu
Journal:  BMC Cardiovasc Disord       Date:  2020-06-03       Impact factor: 2.298

Review 2.  Newer echocardiographic techniques for aortic-valve imaging: Clinical aids today, clinical practice tomorrow.

Authors:  Nidhish Tiwari; Kavisha Patel
Journal:  World J Cardiol       Date:  2018-08-26
  2 in total