Literature DB >> 26674913

Comparative Study of Naugle and Hertel Exophthalmometry in Orbitozygomatic Fracture.

Hong Bae Jeon1, Dong Hee Kang, Sang Ah Oh, Ja Hea Gu.   

Abstract

Accurate perioperative evaluation of enophthalmos is important to determine the adequacy of surgical repair in orbitozygomatic fracture. In this study, the authors evaluated the degree of enophthalmos using Hertel and Naugle exophthalmometry in patients with pure blowout fracture and orbitozygomatic fracture, and compared the results. Fifty patients were divided into 2 groups: pure blowout fracture (Group A: control group, 25 patients) and orbitozygomatic fracture with displaced lateral orbital rim (Group B: experimental group, 25 patients). Hertel and Naugle scales were measured before and 6 months after surgery. The degree of lateral orbital rim advancement was assessed by comparing the difference between the perioperative change of the Hertel and Naugle scales. In Group A, the difference between the pre- and postoperative scales in the 2 exophthalmometry was statistically significant (P < 0.05). In Group B, the Hertel scale increased from -0.20 to -0.16 mm, with an insignificant difference between pre- and postoperative values (P > 0.05) and the Naugle scale increased from -0.88 to -0.20 mm, with a significant difference (P < 0.05). The Δ Hertel scale differed from the Δ Naugle scale by a mean of -0.64 mm, which represents the degree of lateral orbital rim advancement. Naugle exophthalmometry is a more reliable method for evaluation of enophthalmos in lateral orbital rim displaced orbitozygomatic fractures than Hertel exophthalmometry. The degree of lateral orbital rim advancement can be assessed by combined use of the Hertel and Naugle exophthalmometry in orbitozygomatic fractures.

Entities:  

Mesh:

Year:  2016        PMID: 26674913     DOI: 10.1097/SCS.0000000000002334

Source DB:  PubMed          Journal:  J Craniofac Surg        ISSN: 1049-2275            Impact factor:   1.046


  3 in total

1.  Orbital wall restoring surgery with primary orbital wall fragments in blowout fracture.

Authors:  Dong Hee Kang
Journal:  Arch Craniofac Surg       Date:  2019-12-20

2.  Measurement of proptosis using computed tomography based three-dimensional reconstruction software in patients with Graves' orbitopathy.

Authors:  Jung Huh; Sang Joon Park; Jeong Kyu Lee
Journal:  Sci Rep       Date:  2020-09-03       Impact factor: 4.379

3.  Computer-Assisted Secondary Orbital Reconstruction.

Authors:  Daman D Singh; Lara Schorn; E Bradley Strong; Michael Grant; Alexander Schramm; Karsten Hufendiek; Nils-Claudius Gellrich; Majeed Rana
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2020-07-09
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.