Literature DB >> 2667384

Color flow duplex screening of infrainguinal grafts combining low- and high-velocity criteria.

J G Sladen1, J D Reid, P L Cooperberg, P B Harrison, T M Maxwell, M O Riggs, L D Sanders.   

Abstract

The aim of this prospective study was to evaluate the ability of duplex ultrasonography to identify infrainguinal grafts at high risk for failure. The criteria used identified low flow by low peak systolic velocity (less than 45 cm/s) and stenosis by high velocity (greater than 300 cm/s) or by velocity at the stenosis three times the velocity in the adjacent normal graft. A total of 114 patent grafts were scanned and compared with concurrent angiograms. Duplex scanning correctly identified 18 high-risk grafts by low-flow criteria and an additional 21 by stenosis criteria. There was one false-negative finding (sensitivity 98 percent). The velocity ratio of the stenosis to the adjacent graft was useful in estimating the degree of stenosis. Color flow duplex imaging reduced examination time through visual feedback by highlighting the graft and areas of high velocity. These results indicate that color flow duplex scanning, combining low- and high-peak systolic criteria, is a very sensitive screening test in the early detection of failing grafts.

Entities:  

Mesh:

Year:  1989        PMID: 2667384     DOI: 10.1016/0002-9610(89)90356-5

Source DB:  PubMed          Journal:  Am J Surg        ISSN: 0002-9610            Impact factor:   2.565


  2 in total

1.  Asia-Pacific Consensus Statement on the Management of Peripheral Artery Disease: A Report from the Asian Pacific Society of Atherosclerosis and Vascular Disease Asia-Pacific Peripheral Artery Disease Consensus Statement Project Committee.

Authors:  Maria Teresa B Abola; Jonathan Golledge; Tetsuro Miyata; Seung-Woon Rha; Bryan P Yan; Timothy C Dy; Marie Simonette V Ganzon; Pankaj Kumar Handa; Salim Harris; Jiang Zhisheng; Ramakrishna Pinjala; Peter Ashley Robless; Hiroyoshi Yokoi; Elaine B Alajar; April Ann Bermudez-Delos Santos; Elmer Jasper B Llanes; Gay Marjorie Obrado-Nabablit; Noemi S Pestaño; Felix Eduardo Punzalan; Bernadette Tumanan-Mendoza
Journal:  J Atheroscler Thromb       Date:  2020-07-04       Impact factor: 4.928

2.  One-point measurement of the peak-to-peak pulsatility index as an indicator for evaluation of infrainguinal bypass procedures.

Authors:  Y Inoue; T Iwai; T Kubota; N Kure; Y Muraoka; M Endo
Journal:  Surg Today       Date:  1997       Impact factor: 2.549

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.