Clutter filtering influence on blood velocity estimation using speckle tracking.

Solveig Fadnes, Steinar Bjærum, Hans Torp, Lasse Lovstakken.   

Abstract

Blood speckle tracking has shown potential for solving the angle-dependency limitation in color flow imaging. However, as clutter filtering is still Doppler-based, flow velocities at near-perpendicular beam-to-flow angles can be severely attenuated. It is shown that the clutter filter also alters the speckle appearance through a decrease in the lateral imaging bandwidth, leading to poorer lateral resolution and thus tracking performance. Interestingly, at perpendicular beam-to-flow angles lateral band-pass characteristics are inferred, and the resulting lateral amplitude modulation could help improve tracking estimates. Simulations and flow phantom experiments showed that substantially improved results could be achieved by utilizing time-variant clutter filters (e.g., polynomial regression filters) despite the inherent decorrelation inferred by these filters, but only for higher ensemble sizes (N > 36). We found that, compared with color flow imaging, speckle tracking could yield consistent estimates well below the clutter filter cutoff, but with a higher variance attributed to the low signalto- noise ratio inferred by filter attenuation. Overall, provided that a low f-number and high ensemble lengths (N approx. > 36) can be used, speckle tracking can consistently provide angle- independent flow velocity estimates, limited only by a lower bound on the flow velocity itself.

Mesh:

Year:  2015        PMID: 26670849     DOI: 10.1109/TUFFC.2015.007247

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  5 in total

1.  Combining Slow Flow Techniques With Adaptive Demodulation for Improved Perfusion Ultrasound Imaging Without Contrast.

Authors:  Jaime Tierney; Kristy Walsh; Helen Griffith; Jennifer Baker; Daniel B Brown; Brett Byram
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-02-07       Impact factor: 2.725

2.  Adaptive Clutter Demodulation for Non-Contrast Ultrasound Perfusion Imaging.

Authors:  Jaime Tierney; Crystal Coolbaugh; Theodore Towse; Brett Byram
Journal:  IEEE Trans Med Imaging       Date:  2017-06-13       Impact factor: 10.048

3.  In vivo imaging of ocular blood flow using high-speed ultrasound.

Authors:  Jeffrey A Ketterling; Raksha Urs; Ronald H Silverman
Journal:  IEEE Int Ultrason Symp       Date:  2016-11-03

4.  Characterization of Vortex Flow in a Mouse Model of Ventricular Dyssynchrony by Plane-Wave Ultrasound Using Hexplex Processing.

Authors:  Akshay Shekhar; Orlando Aristizabal; Glenn I Fishman; Colin K L Phoon; Jeffrey A Ketterling
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2021-02-25       Impact factor: 2.725

5.  High-speed, high-frequency ultrasound, in utero vector-flow imaging of mouse embryos.

Authors:  Jeffrey A Ketterling; Orlando Aristizábal; Billy Y S Yiu; Daniel H Turnbull; Colin K L Phoon; Alfred C H Yu; Ronald H Silverman
Journal:  Sci Rep       Date:  2017-11-30       Impact factor: 4.379