Literature DB >> 26669805

Three-Dimensional Echocardiography in the Evaluation of Right Ventricular Global and Regional Systolic Function in Patients with Atrial Septal Defect before and after Percutaneous Closure.

Dehong Kong1,2,3, Leilei Cheng1,2,3, Lili Dong1,2,3, Cuizhen Pan1,2,3, Haohua Yao1,2,3, Daxin Zhou2, Xianhong Shu1,2,3.   

Abstract

OBJECTIVE: To evaluate right ventricular (RV) global and regional systolic function in patients with atrial septal defect (ASD) before and after percutaneous closure using real time three-dimensional echocardiography (RT3DE).
METHODS: RT3DE was performed in 81 patients with ASD within 24 hours before and after percutaneous closure to obtain RV global and regional ejection fraction (EF) in three compartments (inflow, body, and outflow). RV fractional area change (FAC), tricuspid annular plane systolic excursion (TAPSE), peak tricuspid systolic velocity (S), and pulmonary vascular resistance (PVR) were recorded. Forty matched normal adults were included as controls.
RESULTS: When compared with controls, RV global and regional EF were decreased in preclosure patients (P < 0.001). FAC was lower while TAPSE and S were higher in preclosure patients than in controls (P < 0.05). After closure, RV systolic function parameters were all reduced (P < 0.001). Regional EF in the body compartment was the lowest among the three compartments in ASD patients (P < 0.05). Procedural percentage changes of RV global EF and regional EF in the inflow compartment were lower than those of two-dimensional systolic function parameters (P < 0.05). RV global and regional EF in the inflow compartment were negatively correlated with PVR in patients after closure (r = -0.601, -0.543, P < 0.001).
CONCLUSIONS: RV global and regional systolic functions are impaired in open and closed ASD. RT3DE-derived systolic function parameters are negatively correlated with RV after load. RT3DE has potential value in the evaluation of RV systolic function in patients with ASD.
© 2015, Wiley Periodicals, Inc.

Entities:  

Keywords:  atrial septal defect; right ventricular function; systolic function; three-dimensional echocardiography

Mesh:

Year:  2015        PMID: 26669805     DOI: 10.1111/echo.13134

Source DB:  PubMed          Journal:  Echocardiography        ISSN: 0742-2822            Impact factor:   1.724


  6 in total

Review 1.  Echocardiographic guidance of interventions in adults with congenital heart defects.

Authors:  Weiyi Tan; Jamil Aboulhosn
Journal:  Cardiovasc Diagn Ther       Date:  2019-10

2.  Dynamic characteristic mechanism of atrial septal defect using real-time three-dimensional echocardiography and evaluation of right ventricular functions.

Authors:  Gao-Wa Sharen; Jun Zhang; Chuan Qin; Qing Lv
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2017-02-22

3.  Left and right ventricular speckle tracking study before and after percutaneous atrial septal defect closure in children.

Authors:  Hala M Agha; Islam S Mohammed; Hassan A Hassan; Hassan S Abu Seif; Ibrahim M Abu Farag
Journal:  J Saudi Heart Assoc       Date:  2020-04-17

Review 4.  Three-Dimensional Echocardiography Assessment of Right Ventricular Volumes and Function: Technological Perspective and Clinical Application.

Authors:  Ashfaq Ahmad; He Li; Yanting Zhang; Juanjuan Liu; Ying Gao; Mingzhu Qian; Yixia Lin; Luyang Yi; Li Zhang; Yuman Li; Mingxing Xie
Journal:  Diagnostics (Basel)       Date:  2022-03-25

Review 5.  Three-dimensional echocardiography in adult congenital heart disease.

Authors:  Hyun Suk Yang
Journal:  Korean J Intern Med       Date:  2017-06-30       Impact factor: 2.884

6.  Impact of Right Ventricular Dilatation in Patients with Atrial Septal Defect.

Authors:  Rie Nakayama; Yoichi Takaya; Teiji Akagi; Koji Nakagawa; Nobuhisa Watanabe; Saori Nobusada; Toshi Matsushita; Norihisa Toh; Susumu Kanazawa; Hiroshi Ito
Journal:  J Interv Cardiol       Date:  2020-04-27       Impact factor: 2.279

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.