Literature DB >> 26668816

Optimized multimodal functional magnetic resonance imaging/near-infrared spectroscopy probe for ultrahigh-resolution mapping.

Lia Maria Hocke1, Kenroy Cayetano2, Yunjie Tong2, Blaise Frederick2.   

Abstract

Functional near-infrared spectroscopy (fNIRS) is an increasingly important noninvasive method in neuroscience due to its high temporal resolution and ability to independently measure oxy- and deoxy-hemoglobin. However, the relatively low spatial resolution of fNIRS makes it difficult to relate this signal to underlying anatomy. Simultaneous functional magnetic resonance imaging (fMRI) can complement fNIRS with superior spatial resolution and the ability to image the entire brain, providing additional information to improve fNIRS localization. However, current simultaneous fMRI/fNIRS acquisition methods are not optimal, due to the poor physical compatibility of existing MR coils and fNIRS optodes. Here, we present a technique to manufacture a true multimodal fMRI/fNIRS probe in which both modalities can be used with maximal sensitivity. To achieve this, we designed custom MR coils with integral fNIRS optodes using three-dimensional printing. This multimodal probe can be used to optimize spatial ([Formula: see text]) and temporal resolution (2.5 Hz) of fMRI, and it provides maximal MRI sensitivity, while allowing for high flexibility in the location and density of fNIRS optodes within the area of interest. Phantom and human data are shown to confirm the improvement in sensitivity in both modalities. This probe shows promise for addressing fundamental questions of the relation of fNIRS to physiology.

Entities:  

Keywords:  functional magnetic resonance imaging; functional near-infrared spectroscopy; optics; simultaneous measurements; ultra-high spatial resolution; ultra-high temporal resolution

Year:  2015        PMID: 26668816      PMCID: PMC4675318          DOI: 10.1117/1.NPh.2.4.045004

Source DB:  PubMed          Journal:  Neurophotonics        ISSN: 2329-423X            Impact factor:   3.593


  47 in total

1.  Improved optimization for the robust and accurate linear registration and motion correction of brain images.

Authors:  Mark Jenkinson; Peter Bannister; Michael Brady; Stephen Smith
Journal:  Neuroimage       Date:  2002-10       Impact factor: 6.556

Review 2.  Report on a multicenter fMRI quality assurance protocol.

Authors:  Lee Friedman; Gary H Glover
Journal:  J Magn Reson Imaging       Date:  2006-06       Impact factor: 4.813

3.  Illuminating the BOLD signal: combined fMRI-fNIRS studies.

Authors:  Jens Steinbrink; Arno Villringer; Florian Kempf; Daniel Haux; Stefanie Boden; Hellmuth Obrig
Journal:  Magn Reson Imaging       Date:  2006-03-20       Impact factor: 2.546

Review 4.  Advances in functional and structural MR image analysis and implementation as FSL.

Authors:  Stephen M Smith; Mark Jenkinson; Mark W Woolrich; Christian F Beckmann; Timothy E J Behrens; Heidi Johansen-Berg; Peter R Bannister; Marilena De Luca; Ivana Drobnjak; David E Flitney; Rami K Niazy; James Saunders; John Vickers; Yongyue Zhang; Nicola De Stefano; J Michael Brady; Paul M Matthews
Journal:  Neuroimage       Date:  2004       Impact factor: 6.556

5.  A quantitative comparison of NIRS and fMRI across multiple cognitive tasks.

Authors:  Xu Cui; Signe Bray; Daniel M Bryant; Gary H Glover; Allan L Reiss
Journal:  Neuroimage       Date:  2010-11-01       Impact factor: 6.556

6.  Proton spectroscopic imaging of the human brain using phased array detectors.

Authors:  L L Wald; S E Moyher; M R Day; S J Nelson; D B Vigneron
Journal:  Magn Reson Med       Date:  1995-09       Impact factor: 4.668

7.  Comparison of finite-difference transport and diffusion calculations for photon migration in homogeneous and heterogeneous tissues.

Authors:  A H Hielscher; R E Alcouffe; R L Barbour
Journal:  Phys Med Biol       Date:  1998-05       Impact factor: 3.609

8.  Visualization of light propagation in visible Chinese human head for functional near-infrared spectroscopy.

Authors:  Ting Li; Hui Gong; Qingming Luo
Journal:  J Biomed Opt       Date:  2011-04       Impact factor: 3.170

9.  Multiband multislice GE-EPI at 7 tesla, with 16-fold acceleration using partial parallel imaging with application to high spatial and temporal whole-brain fMRI.

Authors:  Steen Moeller; Essa Yacoub; Cheryl A Olman; Edward Auerbach; John Strupp; Noam Harel; Kâmil Uğurbil
Journal:  Magn Reson Med       Date:  2010-05       Impact factor: 4.668

10.  Estimation of optical pathlength through tissue from direct time of flight measurement.

Authors:  D T Delpy; M Cope; P van der Zee; S Arridge; S Wray; J Wyatt
Journal:  Phys Med Biol       Date:  1988-12       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.