Literature DB >> 26665952

[Mobile Health: IEEE Standard for Wearable Cuffless Blood Pressure Measuring Devices].

Xia Zhou, Wenli Wu, Shudi Bao.   

Abstract

IEEE Std 1708-2014 breaks through the traditional standards of cuff based blood pressure measuring devices and establishes a normative definition of wearable cuffless blood pressure measuring devices and the objective performance evaluation of this kind of devices. This study firstly introduces the background of the new standard. Then, the standard details will be described, and the impact of cuffless blood pressure measuring devices with the new standard on manufacturers and end users will be addressed.

Mesh:

Year:  2015        PMID: 26665952

Source DB:  PubMed          Journal:  Zhongguo Yi Liao Qi Xie Za Zhi        ISSN: 1671-7104


  7 in total

1.  Toward Ubiquitous Blood Pressure Monitoring via Pulse Transit Time: Theory and Practice.

Authors:  Ramakrishna Mukkamala; Jin-Oh Hahn; Omer T Inan; Lalit K Mestha; Chang-Sei Kim; Hakan Töreyin; Survi Kyal
Journal:  IEEE Trans Biomed Eng       Date:  2015-06-05       Impact factor: 4.538

2.  Wearable Cuff-Less Blood Pressure Estimation at Home via Pulse Transit Time.

Authors:  Venu G Ganti; Andrew M Carek; Brandi N Nevius; J Alex Heller; Mozziyar Etemadi; Omer T Inan
Journal:  IEEE J Biomed Health Inform       Date:  2021-06-03       Impact factor: 7.021

3.  Pulse Transit Time Based Continuous Cuffless Blood Pressure Estimation: A New Extension and A Comprehensive Evaluation.

Authors:  Xiaorong Ding; Bryan P Yan; Yuan-Ting Zhang; Jing Liu; Ni Zhao; Hon Ki Tsang
Journal:  Sci Rep       Date:  2017-09-14       Impact factor: 4.379

4.  Feasibility of a New Cuffless Device for Ambulatory Blood Pressure Measurement in Patients With Hypertension: Mixed Methods Study.

Authors:  Paula Am Ogink; Jelske M de Jong; Mats Koeneman; Mariska Weenk; Lucien Jlpg Engelen; Harry van Goor; Tom H van de Belt; Sebastian Jh Bredie
Journal:  J Med Internet Res       Date:  2019-06-19       Impact factor: 5.428

5.  Combined deep CNN-LSTM network-based multitasking learning architecture for noninvasive continuous blood pressure estimation using difference in ECG-PPG features.

Authors:  Da Un Jeong; Ki Moo Lim
Journal:  Sci Rep       Date:  2021-06-29       Impact factor: 4.379

6.  Blood pressure measurements with the OptiBP smartphone app validated against reference auscultatory measurements.

Authors:  Patrick Schoettker; Jean Degott; Gregory Hofmann; Martin Proença; Guillaume Bonnier; Alia Lemkaddem; Mathieu Lemay; Raoul Schorer; Urvan Christen; Jean-François Knebel; Arlene Wuerzner; Michel Burnier; Gregoire Wuerzner
Journal:  Sci Rep       Date:  2020-10-20       Impact factor: 4.379

7.  Evaluation of the Accuracy of a New Cuffless Magnetoplethysmography Blood Pressure Monitor in Hypertensive Patients.

Authors:  Sua Kim; Jung Dong Lee; Jeong Bae Park; Seungjin Jang; Jungchae Kim; Sang-Suk Lee
Journal:  Pulse (Basel)       Date:  2018-02-15