| Literature DB >> 26663256 |
Shihong Liu1, Jingmin Shi2, Junpei Fan2, Jie Sun2, Suhui Zhang2, Yue Hu2, Li Wei1,2, Chunhua Wu1, Xiuli Chang1, Liming Tang2, Zhijun Zhou1.
Abstract
A precise, high-throughput and sensitive ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method has been developed for the determination of fluorochloridone (FLC) in rat plasma. The extraction of analytes from plasma samples was carried out by protein precipitation procedure using acetonitrile prior to UPLC-MS/MS analysis. Verapamil was proved as a proper internal standard (IS) among many candidates. The chromatographic separation based on UPLC was well optimized. Multiple reaction monitoring in positive electrospray ionization was used with the optimized MS transitions at: m/z 312.0 → 292.0 for FLC and m/z 456.4 → 165.2 for IS. This method was well validated with good linear response (r(2) > 0.998) observed over the investigated range of 3-3000 ng/mL and with satisfactory stability. This method was also characterized with adequate intra- and inter-day precision and accuracy (within 12%) in the quality control samples, and with high selectivity and less matrix effect observed. Total running time was only 1.5 min. This method has been successfully applied to a pilot FLC pharmacokinetic study after oral administration.Entities:
Keywords: UPLC-MS/MS; fluorochloridone; pharmacokinetics; rat plasma
Mesh:
Substances:
Year: 2016 PMID: 26663256 DOI: 10.1002/bmc.3666
Source DB: PubMed Journal: Biomed Chromatogr ISSN: 0269-3879 Impact factor: 1.902