Bacteriology testing of cardiovascular tissues: comparison of transport solution versus tissue testing.

R Díaz Rodríguez1, B Van Hoeck2, B Mujaj2, R Ngakam2, Y Fan2, K Bogaerts3,4, R Jashari2.   

Abstract

Bacteriology testing is mandatory for quality control of recovered cardiovascular allografts (CVA). In this paper, two different bacteriology examinations (A tests) performed before tissue antibiotic decontamination were compared: transport solution filtration analysis (A1) and tissue fragment direct incubation (A2). For this purpose, 521 CVA (326 heart and 195 artery tissues) from 280 donors were collected and analyzed by the European Homograft Bank (EHB). Transport solution (A1) tested positive in 43.25 % of hearts and in 48.21 % of arteries, whereas the tissue samples (A2) tested positive in 38.34 % of hearts and 33.85 % of arteries. The main species identified in both A1 and A2 were Staphylococcus spp. in 55 and 26 % of cases, and Propionibacterium spp. in 8 and 19 %, respectively. Mismatches in bacteriology results between both initial tests A1 and A2 were found. 18.40 % of the heart valves were identified as positive by A1 whilst 13.50 % were considered positive by A2. For arteries, 20.51 % of cases were positive in A1 and negative in A2, and just 6.15 % of artery allografts presented contamination in the A2 test but were considered negative for the A1 test. Comparison between each A test with the B and C tests after antibiotic treatment of the allograft was also performed. A total decontamination rate of 70.8 % of initial positive A tests was obtained. Due to the described mismatches and different bacteria identification percentage, utilization of both A tests should be implemented in tissue banks in order to avoid false negatives.

Keywords:  Cardiovascular allografts; Comparison of bacteriology tests; False negatives; Mismatches

Mesh:

Substances:

Year:  2015        PMID: 26662518     DOI: 10.1007/s10561-015-9537-2

Source DB:  PubMed          Journal:  Cell Tissue Bank        ISSN: 1389-9333            Impact factor:   1.522


  3 in total

1.  The BD BACTEC FX blood culture system with the gentlemacs dissociator is suitable for sterility testing of heart valve and vascular allografts-A validation study.

Authors:  Ramadan Jashari; Sarah Vanzeebroeck; Pieter Petit; Hector Rodriguez-Villalobos; Sharon Zahra; Naziha Ben Said; Vanessa Bouzet; Stefano Mastrobuoni
Journal:  Cell Tissue Bank       Date:  2021-01-08       Impact factor: 1.522

2.  Does microbiological contamination of homografts prior to decontamination affect the outcome after right ventricular outflow tract reconstruction?

Authors:  Ida Axelsson; Torsten Malm; Johan Nilsson
Journal:  Interact Cardiovasc Thorac Surg       Date:  2021-10-04

3.  Transplantation of cryopreserved human heart valves in Europe: 30 years of banking in Brussels and future perspectives.

Authors:  Ramadan Jashari
Journal:  Cell Tissue Bank       Date:  2021-02-02       Impact factor: 1.522

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.