Literature DB >> 2666046

A prospective comparison of IMV and T-piece weaning from mechanical ventilation.

J R Tomlinson1, K S Miller, D G Lorch, L Smith, H D Reines, S A Sahn.   

Abstract

Two hundred (200) consecutive medical and surgical patients requiring mechanical ventilation were entered into a prospective randomized trial of weaning by either intermittent mandatory ventilation (IMV) or T-piece. Patients in these groups were of similar age and sex and had the same total ventilation time (TVT). The study design provided equal time for each weaning mode after specific criteria for oxygenation and ventilation were satisfied (PaO2 greater than 55 mm Hg on FIO2 less than 0.5; VE less than 12 L/min and two of the following four parameters: MVV greater than 2 VE, VT greater than 5 ml/kg, FVC greater than 10 ml/kg, NIF less than or equal to -20 cm H2O). Of the original 200 patients 165 were entered into the weaning phase; 35 patients were withdrawn prior to weaning due to the discretion of the attending physician or protocol error. Weaning time was not different between the IMV (5.3 +/- 1.2 h, mean +/- SEM) and T-piece groups (5.9 +/- 1.4 h, p = NS). Of the 165 patients, 155 (93 percent) were weaned successfully by protocol, 79 in the IMV and 76 in the T-piece group. Of 155 patients, 136 (88 percent) were weaned on the first attempt by protocol. Of the 19 who were not weaned, 11 were weaned successfully on the second and five on the third trial; three patients required three-day weans. We conclude that clinically stable patients who require short-term mechanical ventilation and meet standard bedside weaning criteria can be weaned efficiently by protocol using either IMV or T-piece techniques.

Entities:  

Mesh:

Year:  1989        PMID: 2666046     DOI: 10.1378/chest.96.2.348

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  5 in total

Review 1.  Difficult weaning from mechanical ventilation.

Authors:  J C Chevrolet
Journal:  Lung       Date:  1990       Impact factor: 2.584

Review 2.  Consensus conference on mechanical ventilation--January 28-30, 1993 at Northbrook, Illinois, USA. Part 2.

Authors:  A S Slutsky
Journal:  Intensive Care Med       Date:  1994       Impact factor: 17.440

Review 3.  Noninvasive positive-pressure ventilation as a weaning strategy for intubated adults with respiratory failure.

Authors:  Karen E A Burns; Maureen O Meade; Azra Premji; Neill K J Adhikari
Journal:  Cochrane Database Syst Rev       Date:  2013-12-09

Review 4.  Our paper 20 years later: how has withdrawal from mechanical ventilation changed?

Authors:  Fernando Frutos-Vivar; Andrés Esteban
Journal:  Intensive Care Med       Date:  2014-07-23       Impact factor: 17.440

5.  Clinical verification of a clinical decision support system for ventilator weaning.

Authors:  Jiin-Chyr Hsu; Yung-Fu Chen; Wei-Sheng Chung; Tan-Hsu Tan; Tainsong Chen; John Y Chiang
Journal:  Biomed Eng Online       Date:  2013-12-09       Impact factor: 2.819