Literature DB >> 26660187

Quantification of Iohexol in Serum by High-Performance Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS).

Faye B Vicente1, Gina Vespa1, Alan Miller1, Shannon Haymond2.   

Abstract

Iohexol is a nonradioactive contrast medium, and its clearance from serum or urine is used to measure glomerular filtration rate (GFR). GFR is the most useful indicator of kidney function and progression of kidney disease. GFR determination using iohexol clearance is increasingly being applied in clinical practice, given its advantages over and correlation with inulin. We describe a high-performance liquid chromatography tandem mass spectrometry (LC-MS/MS) method for iohexol clearance, requiring only 50 μL of serum. The sample preparation involves protein precipitation with LC/MS-grade methanol, containing ioversol as the internal standard. Samples are centrifuged and supernatant is dried under nitrogen gas at room temperature. Samples are reconstituted with mobile phase (ammonium acetate-formic acid-water). Iohexol is separated using an HPLC gradient method on a C-8 analytical column. MS/MS detection is in the multiple-reaction monitoring (MRM) mode and the transitions monitored are m/z 822.0 to m/z 804.0 and m/z 807.0 to m/z 588.0 for iohexol and ioversol, respectively.

Entities:  

Keywords:  Glomerular filtration rate; Iohexol; Liquid chromatography; Mass spectrometry; Quantification; Serum

Mesh:

Substances:

Year:  2016        PMID: 26660187     DOI: 10.1007/978-1-4939-3252-8_20

Source DB:  PubMed          Journal:  Methods Mol Biol        ISSN: 1064-3745


  2 in total

1.  A convenient online desalination tube coupled with mass spectrometry for the direct detection of iodinated contrast media in untreated human spent hemodialysates.

Authors:  Md Mahamodun Nabi; Takumi Sakamoto; Md Al Mamun; Ariful Islam; A S M Waliullah; Shuhei Aramaki; Md Mahmudul Hasan; Shingo Ema; Akihiko Kato; Yutaka Takahashi; Tomoaki Kahyo; Mitsutoshi Setou; Tomohito Sato
Journal:  PLoS One       Date:  2022-06-06       Impact factor: 3.752

2.  Iohexol plasma clearance for measuring glomerular filtration rate in clinical practice and research: a review. Part 1: How to measure glomerular filtration rate with iohexol?

Authors:  Pierre Delanaye; Natalie Ebert; Toralf Melsom; Flavio Gaspari; Christophe Mariat; Etienne Cavalier; Jonas Björk; Anders Christensson; Ulf Nyman; Esteban Porrini; Giuseppe Remuzzi; Piero Ruggenenti; Elke Schaeffner; Inga Soveri; Gunnar Sterner; Bjørn Odvar Eriksen; Sten-Erik Bäck
Journal:  Clin Kidney J       Date:  2016-08-23