Literature DB >> 26658566

No differences in functional results and quality of life after single-radius or multiradius TKA.

Pedro Hinarejos1, Lluis Puig-Verdie2, Joan Leal2, Xavier Pelfort2, Raul Torres-Claramunt2, Juan Sánchez-Soler2, Joan C Monllau2.   

Abstract

PURPOSE: The main objective of this study was to compare the functional results and the impact on quality of life after a single-radius or a multiradius TKA implantation. The secondary objectives were to compare range of motion, satisfaction and the ability to perform daily life activities with both types of implant. It was hypothesized that the single-radius TKA would lead to better functional results and better quality of life than the multiradius TKA.
METHODS: This is a prospective non-randomized study that included 250 cases of a single-radius TKA and 224 of a multiradius posterior-stabilized TKA implanted with the same surgical and rehabilitation protocol.
RESULTS: In the 1- and 5-year follow-up, we found similar knee KSS scores (89.7 ± 12.1 in the multiradius group and 90.3 ± 11.7 in the single-radius group) and functional KSS scores (78.6 ± 21.4 in the multiradius group and 75.8 ± 20.9 in the single-radius group). The pain and the Physical SF-36 scores were also similar. Range of motion (112° ± 12° in the multiradius group and 112 ± 12° in the single-radius group), patients' satisfaction and the ability to perform daily life activities were also similar in both groups.
CONCLUSION: The use of a single-radius or a multiradius posterior-stabilized knee prosthesis can improve the function of the knee and the patients' quality of life in a similar way at the short-term and midterm follow-up. Moreover, range of motion, patient satisfaction and the ability to perform daily life activities are similar with both types of prosthesis. As both types of prosthesis can improve the function and quality of life of the patients in a similar way, the sagittal radius of the femoral component should not be considered the main factor when choosing the model of TKA. LEVEL OF EVIDENCE: Therapeutic study: Prospective comparative study, Level II.

Entities:  

Keywords:  Function; Multiradius; Quality of life; Single radius; TKA; TKR; Total knee arthroplasty; Total knee replacement

Mesh:

Year:  2015        PMID: 26658566     DOI: 10.1007/s00167-015-3894-z

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.342


  30 in total

1.  Single radius total knee arthroplasty: PCL sacrifice without substitution yields excellent outcomes minimum 8-year follow-up.

Authors:  Steven F Harwin; Mark Kester
Journal:  Surg Technol Int       Date:  2010-04

2.  Factors influencing range of motion after contemporary total knee arthroplasty.

Authors:  Akihiro Kotani; Akihiko Yonekura; Robert B Bourne
Journal:  J Arthroplasty       Date:  2005-10       Impact factor: 4.757

3.  Scorpio single radius total knee arthroplasty. A minimal five-year follow-up multicentric study.

Authors:  Frédéric Borrione; Paul Bonnevialle; Christian Mabit; Olivier Guingand; Denis Bertin; François Bonnomet; Christophe Denis; Gilles Gagna
Journal:  Int Orthop       Date:  2011-03-02       Impact factor: 3.075

4.  Single-radius, multidirectional total knee replacement.

Authors:  Jean-Yves Jenny; Rolf Miehlke; Dominique Saragaglia; Robert Geyer; Numa Mercier; Jean-Yves Schoenahl; Birger Thiel
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-08-28       Impact factor: 4.342

5.  A comparison of stability and clinical outcomes in single-radius versus multi-radius femoral design for total knee arthroplasty.

Authors:  Ah-Reum Jo; Eun-Kyoo Song; Keun-Bae Lee; Hyoung-Yeon Seo; Sung-Kyu Kim; Jong-Keun Seon
Journal:  J Arthroplasty       Date:  2014-03-31       Impact factor: 4.757

6.  Osteoarthrosis of the knee. A radiographic investigation.

Authors:  S Ahlbäck
Journal:  Acta Radiol Diagn (Stockh)       Date:  1968

7.  Biomechanical differences exhibited during sit-to-stand between total knee arthroplasty designs of varying radii.

Authors:  He Wang; Kathy J Simpson; Michael S Ferrara; Samatchai Chamnongkich; Tracy Kinsey; Ormonde M Mahoney
Journal:  J Arthroplasty       Date:  2006-12       Impact factor: 4.757

8.  Translation and validation of 'The Knee Society Clinical Rating System' into Spanish.

Authors:  Oscar Ares; Enric Castellet; Francisco Maculé; Vicenç León; Elvira Montañez; Alicia Freire; Pedro Hinarejos; Ferran Montserrat; Juan Ramon Amillo
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-01-25       Impact factor: 4.342

9.  Five-year survivorship and patient-reported outcome of the Triathlon single-radius total knee arthroplasty.

Authors:  Chloe E H Scott; Nick D Clement; Deborah J MacDonald; David F Hamilton; Paul Gaston; Colin R Howie; Richard Burnett
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-03-13       Impact factor: 4.342

10.  Does a new knee design perform as well as the design it replaces?

Authors:  M Molt; P Ljung; S Toksvig-Larsen
Journal:  Bone Joint Res       Date:  2012-12-01       Impact factor: 5.853

View more
  3 in total

1.  Better functional outcome after single-radius TKA compared with multi-radius TKA.

Authors:  Isabel Collados-Maestre; Alejandro Lizaur-Utrilla; Blanca Gonzalez-Navarro; Francisco A Miralles-Muñoz; Luis Marco-Gomez; Fernando A Lopez-Prats; Vicente Gil-Guillen
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-08-13       Impact factor: 4.342

2.  Comparison of Single-Radius with Multiple-Radius Femur in Total Knee Arthroplasty: A Meta-Analysis of Prospective Randomized Controlled Trials.

Authors:  Ting Lei; Zichao Jiang; Hu Qian; David Backstein; Pengfei Lei; Yihe Hu
Journal:  Orthop Surg       Date:  2022-08-04       Impact factor: 2.279

3.  A Systematic Review of Clinical Functional Outcomes After Medial Stabilized Versus Non-Medial Stabilized Total Knee Joint Replacement.

Authors:  Tony Young; Michelle M Dowsey; Marcus Pandy; Peter F Choong
Journal:  Front Surg       Date:  2018-04-11