Yohei Yamamoto1, Satoshi Yamaguchi2, Takahisa Sasho1, Taisuke Fukawa1, Yorikazu Akatsu1, Kengo Nagashima1, Kazuhisa Takahashi1. 1. Department of Orthopedic Surgery, Graduate School of Medical and Pharmaceutical Sciences, Chiba University, Chiba, Japan (Y.Y., S.Y., T.S., T.F., Y.A., K.T.); and Clinical Research Center, Chiba University Hospital, Chiba, Japan (K.N.). 2. Department of Orthopedic Surgery, Graduate School of Medical and Pharmaceutical Sciences, Chiba University, Chiba, Japan (Y.Y., S.Y., T.S., T.F., Y.A., K.T.); and Clinical Research Center, Chiba University Hospital, Chiba, Japan (K.N.). y-satoshi@mvb.biglobe.ne.jp.
Abstract
OBJECTIVES: The purposes of this study were to measure intraobserver and interobserver repeatability of quantitative elastography using an acoustic coupler for the Achilles tendon, to compare elastographic values among different age groups, and to assess the correlation between quantitative and conventional qualitative measurements. METHODS: One hundred asymptomatic Achilles tendons of 50 volunteers were examined. For quantitative elastography, the strain value of the tendon was divided by that of the acoustic coupler with a known Young modulus, and the strain ratio was calculated. B-mode image assessment and qualitative elastography were also performed. Intraobserver repeatability and interobserver repeatability of strain ratio measurements were calculated. The strain ratios were compared among age groups by the Kruskal-Wallis test. Additionally, strain ratios for each B-mode grade and qualitative elastographic grade were compared by the Wilcoxon signed rank test. RESULTS: Intraobserver repeatability intraclass correlation coefficient (1, 3) values were 0.87 and 0.93, respectively. The correlation coefficient between the observers' measurements was 0.61. The strain ratio for the 30s age group was 0.27, which was significantly lower than the values for the other age groups (P < .001). Although 97 of 100 tendons were normal on B-mode evaluations, 36 of the 97 tendons were degenerated on qualitative elastography and also had higher strain ratio values than normal tendons. CONCLUSIONS: Quantitative elastography using an acoustic coupler is a reproducible technique for measuring the elasticity of the Achilles tendon. It may detect early tendon degeneration that is not depicted on B-mode imaging.
OBJECTIVES: The purposes of this study were to measure intraobserver and interobserver repeatability of quantitative elastography using an acoustic coupler for the Achilles tendon, to compare elastographic values among different age groups, and to assess the correlation between quantitative and conventional qualitative measurements. METHODS: One hundred asymptomatic Achilles tendons of 50 volunteers were examined. For quantitative elastography, the strain value of the tendon was divided by that of the acoustic coupler with a known Young modulus, and the strain ratio was calculated. B-mode image assessment and qualitative elastography were also performed. Intraobserver repeatability and interobserver repeatability of strain ratio measurements were calculated. The strain ratios were compared among age groups by the Kruskal-Wallis test. Additionally, strain ratios for each B-mode grade and qualitative elastographic grade were compared by the Wilcoxon signed rank test. RESULTS: Intraobserver repeatability intraclass correlation coefficient (1, 3) values were 0.87 and 0.93, respectively. The correlation coefficient between the observers' measurements was 0.61. The strain ratio for the 30s age group was 0.27, which was significantly lower than the values for the other age groups (P < .001). Although 97 of 100 tendons were normal on B-mode evaluations, 36 of the 97 tendons were degenerated on qualitative elastography and also had higher strain ratio values than normal tendons. CONCLUSIONS: Quantitative elastography using an acoustic coupler is a reproducible technique for measuring the elasticity of the Achilles tendon. It may detect early tendon degeneration that is not depicted on B-mode imaging.
Authors: Luca Maria Sconfienza; Domenico Albano; Georgina Allen; Alberto Bazzocchi; Bianca Bignotti; Vito Chianca; Fernando Facal de Castro; Elena E Drakonaki; Elena Gallardo; Jan Gielen; Andrea Sabine Klauser; Carlo Martinoli; Giovanni Mauri; Eugene McNally; Carmelo Messina; Rebeca Mirón Mombiela; Davide Orlandi; Athena Plagou; Magdalena Posadzy; Rosa de la Puente; Monique Reijnierse; Federica Rossi; Saulius Rutkauskas; Ziga Snoj; Jelena Vucetic; David Wilson; Alberto Stefano Tagliafico Journal: Eur Radiol Date: 2018-06-06 Impact factor: 5.315
Authors: Enrico M Zardi; Maria Elena Pipita; Chiara Giorgi; Antonella Afeltra; Nicola Maffulli; Francesco Franceschi Journal: In Vivo Date: 2019 Sep-Oct Impact factor: 2.155