Literature DB >> 26657734

Quantitative TLC-Image Analysis of Urinary Creatinine Using Iodine Staining and RGB Values.

Emily Kerr1, Caroline West1, Supaporn Kradtap Hartwell2.   

Abstract

Digital image analysis of the separation results of colorless analytes on thin-layer chromatography (TLC) plates usually involves using specially tailored software to analyze the images generated from either a UV scanner or UV lamp station with a digital camera or a densitometer. Here, a low-cost alternative setup for quantitative TLC-digital image analysis is demonstrated using a universal staining reagent (iodine vapor), an office scanner and a commonly available software (Microsoft Paint) for analysis of red, green and blue colors (RGB values). Urinary creatinine is used as a model analyte to represent a sample in complicated biological matrices. Separation was carried out on a silica gel plate using a butanol-NH4OH-H2O (40 : 10 : 50, v/v) mobile phase with a 6-cm solvent front. It is important that the TLC plate be stained evenly and with sufficient staining time. Staining the TLC plate in a 23.4 × 18.8 × 6.8 cm chamber containing about 70 g iodine crystals yielded comparable results for the staining times of 30-60 min. The Green value offered the best results in the linear working range (0.0810-0.9260 mg/mL) and precision (2.03% RSD, n = 10). The detection limit was found to be 0.24 µg per 3 µL spot. Urinary creatinine concentrations determined by TLC-digital image analysis using the green value calibration graph agree well with results obtained from high-pressure liquid chromatography (HPLC).
© The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26657734      PMCID: PMC4885387          DOI: 10.1093/chromsci/bmv183

Source DB:  PubMed          Journal:  J Chromatogr Sci        ISSN: 0021-9665            Impact factor:   1.618


  9 in total

Review 1.  TLC for pharmaceutical analysis in resource limited countries.

Authors:  Eliangiringa Kaale; Peter Risha; Thomas Layloff
Journal:  J Chromatogr A       Date:  2010-12-13       Impact factor: 4.759

2.  Development and validation of a method for determination of caffeine in diuretic tablets and capsules by high-performance thin-layer chromatography on silica gel plates with a concentration zone using manual spotting and ultraviolet absorption densitometry.

Authors:  Caitlin Sullivan; Joseph Sherma
Journal:  J AOAC Int       Date:  2005 Sep-Oct       Impact factor: 1.913

3.  Evaluation of quantitative thin layer chromatography using staining reagents.

Authors:  Richard Johnsson; Gustav Träff; Martin Sundén; Ulf Ellervik
Journal:  J Chromatogr A       Date:  2007-07-21       Impact factor: 4.759

4.  An image analysis system for thin-layer chromatography quantification and its validation.

Authors:  Tang Tie-xin; Wu Hong
Journal:  J Chromatogr Sci       Date:  2008-07       Impact factor: 1.618

5.  Simultaneous determination of uric acid and creatinine in urine by an eco-friendly solvent-free high performance liquid chromatographic method.

Authors:  Jen-Fon Jen; Shih-Liang Hsiao; Kang-Hsiung Liu
Journal:  Talanta       Date:  2002-10-16       Impact factor: 6.057

6.  Simultaneous determination of creatinine and uric acid in human urine by high-performance liquid chromatography.

Authors:  Yuegang Zuo; Chengjun Wang; Jiping Zhou; Amita Sachdeva; Vanessa C Ruelos
Journal:  Anal Sci       Date:  2008-12       Impact factor: 2.081

7.  Beating the system: a study of a creatinine assay and its efficacy in authenticating human urine specimens.

Authors:  Vincent P Villena
Journal:  J Anal Toxicol       Date:  2010 Jan-Feb       Impact factor: 3.367

8.  Urinary amylase/urinary creatinine ratio (uAm/uCr)--a less-invasive parameter for management of hyperamylasemia.

Authors:  Keita Terui; Tomoro Hishiki; Takeshi Saito; Tetsuya Mitsunaga; Mitsuyuki Nakata; Hideo Yoshida
Journal:  BMC Pediatr       Date:  2013-12-13       Impact factor: 2.125

9.  Validation thin layer chromatography for the determination of acetaminophen in tablets and comparison with a pharmacopeial method.

Authors:  Alina Pyka; Marika Budzisz; Małgorzata Dołowy
Journal:  Biomed Res Int       Date:  2013-08-25       Impact factor: 3.411

  9 in total