Literature DB >> 26655103

Direct injection LC-MS/MS method for the determination of teicoplanin in human plasma.

Kwang-Youl Kim1, Sang-Heon Cho1, Yong-Hyun Song1, Moon-Suk Nam2, Cheol-Woo Kim3.   

Abstract

A direct injection-based, simple, accurate, and robust LC-MS/MS method was developed and validated for the determination of teicoplanin in human plasma. Patient plasma samples were diluted in an aqueous buffer prior to injection into the LC-MS/MS system. Chromatographic separation was achieved using a Cadenza HS-C18 column and a gradient mixture of acetonitrile-water (both containing 0.1% formic acid) as the mobile phase at a flow rate of 0.5mL/min. The analytes were detected in multiple reaction monitoring mode with positive ion electrospray ionization. The concentration of teicoplanin was determined as the sum of six components (A3-1, A2-1, A2-2, A2-3, A2-4, and A2-5). The calibration curve was linear over a concentration range of 1-50mg/L, which covered the clinically accepted trough and therapeutic plasma levels. The intra- and inter-day precision and accuracy values were both less than 15%. This validated method was successfully applied to therapeutic drug monitoring of teicoplanin in routine clinical practice. Thus, we expect it to be useful for the determination of teicoplanin concentration in human plasma.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Direct injection; Multiple reaction monitoring; Teicoplanin; Therapeutic drug monitoring

Mesh:

Substances:

Year:  2015        PMID: 26655103     DOI: 10.1016/j.jchromb.2015.11.037

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  3 in total

1.  A Novel Method for the Determination of Vancomycin in Serum by High-Performance Liquid Chromatography-Tandem Mass Spectrometry and Its Application in Patients with Diabetic Foot Infections.

Authors:  Min Liu; Zhi-Hui Yang; Guo-Hui Li
Journal:  Molecules       Date:  2018-11-10       Impact factor: 4.411

2.  A novel sensitive analytical method for the simultaneous analysis of vancomycin and teicoplanin in human urine via single high-performance liquid chromatography coupled with photodiode array and mass spectrometry in series.

Authors:  Maria Giakoumaki; Yiannis Sarigiannis; Evroula Hapeshi
Journal:  J Sep Sci       Date:  2022-05-20       Impact factor: 3.614

3.  Asymmetric dimethylarginine (ADMA) is identified as a potential biomarker of insulin resistance in skeletal muscle.

Authors:  Woojung Lee; Hyo Jung Lee; Han Byul Jang; Hyo-Jin Kim; Hyo-Jeong Ban; Kwang Youl Kim; Moon Suk Nam; Joo Sun Choi; Kyung-Tae Lee; Seong Beom Cho; Sang Ick Park; Hye-Ja Lee
Journal:  Sci Rep       Date:  2018-02-01       Impact factor: 4.379

  3 in total