Single peak parameters technique for simultaneous measurements: Spectrophotometric sequential injection determination of Fe(II) and Fe(III).

J Kozak1, J Paluch2, A Węgrzecka2, M Kozak3, M Wieczorek2, J Kochana2, P Kościelniak2.   

Abstract

Spectrophotometric sequential injection system (SI) is proposed to automate the method of simultaneous determination of Fe(II) and Fe(III) on the basis of parameters of a single peak. In the developed SI system, sample and mixture of reagents (1,10-phenanthroline and sulfosalicylic acid) are introduced into a vessel, where in an acid environment (pH≅3) appropriate compounds of Fe(II) and Fe(III) with 1,10-phenanthroline and sulfosalicylic acid are formed, respectively. Then, in turn, air, sample, EDTA and sample again, are introduced into a holding coil. After the flow reversal, a segment of air is removed from the system by an additional valve and as EDTA replaces sulfosalicylic acid forming a more stable colorless compound with Fe(III), a complex signal is registered. Measurements are performed at wavelength 530 nm. The absorbance measured at minimum of the negative peak and the area or the absorbance measured at maximum of the signal can be used as measures corresponding to Fe(II) and Fe(III) concentrations, respectively. The time of the peak registration is about 2 min. Two-component calibration has been applied to analysis. Fe(II) and Fe(III) can be determined within the concentration ranges of 0.04-4.00 and 0.1-5.00 mg L(-1), with precision less than 2.8% and 1.7% (RSD), respectively and accuracy better than 7% (RE). The detection limit is 0.04 and 0.09 mg L(-1) for Fe(II) and Fe(III), respectively. The method was applied to analysis of artesian water samples.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Sequential injection analysis; Simultaneous determination of Fe(II) and Fe(III); Two-component analysis

Year:  2015        PMID: 26653493     DOI: 10.1016/j.talanta.2015.06.040

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  2 in total

Review 1.  Flow-Injection Methods in Water Analysis-Recent Developments.

Authors:  Marek Trojanowicz; Marta Pyszynska
Journal:  Molecules       Date:  2022-02-19       Impact factor: 4.411

2.  Separation and Determination of Fe(III) and Fe(II) in Natural and Waste Waters Using Silica Gel Sequentially Modified with Polyhexamethylene Guanidine and Tiron.

Authors:  Svetlana Didukh; Vladimir Losev; Elena Borodina; Nikolay Maksimov; Anatoly Trofimchuk; Olga Zaporogets
Journal:  J Anal Methods Chem       Date:  2017-10-31       Impact factor: 2.193

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.