Literature DB >> 26653478

Rapid amperometric detection of trace metals by inhibition of an ultrathin polypyrrole-based glucose biosensor.

Joseph G Ayenimo1, Samuel B Adeloju2.   

Abstract

A sensitive and reliable inhibitive amperometric glucose biosensor is described for rapid trace metal determination. The biosensor utilises a conductive ultrathin (55 nm thick) polypyrrole (PPy) film for entrapment of glucose oxidase (GOx) to permit rapid inhibition of GOx activity in the ultrathin film upon exposure to trace metals, resulting in reduced glucose amperometric response. The biosensor demonstrates a relatively fast response time of 20s and does not require incubation. Furthermore, a complete recovery of GOx activity in the ultrathin PPy-GOx biosensor is quickly achieved by washing in 2mM EDTA for only 10s. The minimum detectable concentrations achieved with the biosensor for Hg(2+), Cu(2+), Pb(2+) and Cd(2+) by inhibitive amperometric detection are 0.48, 1.5, 1.6 and 4.0 µM, respectively. Also, suitable linear concentration ranges were achieved from 0.48-3.3 µM for Hg(2+), 1.5-10 µM for Cu(2+), 1.6-7.7 µM for Pb(2+) and 4-26 µM for Cd(2+). The use of Dixon and Cornish-Bowden plots revealed that the suppressive effects observed with Hg(2+) and Cu(2+) were via non-competitive inhibition, while those of Pb(2+) and Cd(2+) were due to mixed and competitive inhibition. The stronger inhibition exhibited by the trace metals on GOx activity in the ultrathin PPy-GOx film was also confirmed by the low inhibition constant obtained from this analysis. The biosensor was successfully applied to the determination of trace metals in tap water samples.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Amperometry; Glucose biosensor; Metal ion inhibition; Polypyrrole; Trace metals

Mesh:

Substances:

Year:  2015        PMID: 26653478     DOI: 10.1016/j.talanta.2015.11.024

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  4 in total

1.  Development of glucose oxidase-chitosan immobilized paper biosensor using screen-printed electrode for amperometric detection of Cr(VI) in water.

Authors:  Ajinkya Dabhade; Sivaraman Jayaraman; Balasubramanian Paramasivan
Journal:  3 Biotech       Date:  2021-03-22       Impact factor: 2.406

Review 2.  Enzyme Biosensors for Biomedical Applications: Strategies for Safeguarding Analytical Performances in Biological Fluids.

Authors:  Gaia Rocchitta; Angela Spanu; Sergio Babudieri; Gavinella Latte; Giordano Madeddu; Grazia Galleri; Susanna Nuvoli; Paola Bagella; Maria Ilaria Demartis; Vito Fiore; Roberto Manetti; Pier Andrea Serra
Journal:  Sensors (Basel)       Date:  2016-05-30       Impact factor: 3.576

3.  Inexpensive Bismuth-Film Electrode Supported on Pencil-Lead Graphite for Determination of Pb(II) and Cd(II) Ions by Anodic Stripping Voltammetry.

Authors:  Karen C Bedin; Edson Y Mitsuyasu; Amanda Ronix; André L Cazetta; Osvaldo Pezoti; Vitor C Almeida
Journal:  Int J Anal Chem       Date:  2018-10-08       Impact factor: 1.885

Review 4.  Recent Advancements in Electrochemical Biosensors for Monitoring the Water Quality.

Authors:  Yun Hui; Zhaoling Huang; Md Eshrat E Alahi; Anindya Nag; Shilun Feng; Subhas Chandra Mukhopadhyay
Journal:  Biosensors (Basel)       Date:  2022-07-21
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.