Literature DB >> 26653449

Silver and gold enhancement methods for lateral flow immunoassays.

Myriam Oliveira Rodríguez1, Lucía Blanco Covián1, Agustín Costa García1, Maria Carmen Blanco-López2.   

Abstract

Sensitivity is the main concern at the development of rapid test by lateral flow immunoassays. On the other hand, low limits of detection are often required at medical diagnostics and other field of analysis. To overcome this drawback, several enhancement protocols have been described. In this paper, we have selected different silver enhancement methods and one dual gold conjugation, and we critically compared the amplification produced when applied to a gold-nanoparticle based lateral flow immunoassay for the detection of prostate specific antigen (PSA). The highest amplification was obtained by using an immersion method based on a solution of silver nitrate and hydroquinone/citrate buffer in proportion 1:1. Under these conditions, the system is capable of detecting PSA within 20 min at levels as low as 0.1 ng/mL, with a 3-fold sensitivity improvement.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Dual gold conjugate; Enhancement procedures; Lateral Flow Immunoassay Dipstick; Silver enhancement

Mesh:

Substances:

Year:  2015        PMID: 26653449     DOI: 10.1016/j.talanta.2015.10.068

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  27 in total

Review 1.  Inorganic Complexes and Metal-Based Nanomaterials for Infectious Disease Diagnostics.

Authors:  Christine F Markwalter; Andrew G Kantor; Carson P Moore; Kelly A Richardson; David W Wright
Journal:  Chem Rev       Date:  2018-12-04       Impact factor: 60.622

2.  Novel functionalities of hybrid paper-polymer centrifugal devices for assay performance enhancement.

Authors:  M S Wiederoder; S Smith; P Madzivhandila; D Mager; K Moodley; D L DeVoe; K J Land
Journal:  Biomicrofluidics       Date:  2017-09-12       Impact factor: 2.800

3.  Enhancement of lateral flow immunoassay by alkaline phosphatase: a simple and highly sensitive test for potato virus X.

Authors:  Vasily G Panferov; Irina V Safenkova; Yury A Varitsev; Anatoly V Zherdev; Boris B Dzantiev
Journal:  Mikrochim Acta       Date:  2017-12-06       Impact factor: 5.833

4.  Post-assay growth of gold nanoparticles as a tool for highly sensitive lateral flow immunoassay. Application to the detection of potato virus X.

Authors:  Vasily G Panferov; Irina V Safenkova; Anatoly V Zherdev; Boris B Dzantiev
Journal:  Mikrochim Acta       Date:  2018-10-17       Impact factor: 5.833

Review 5.  Latest Trends in Lateral Flow Immunoassay (LFIA) Detection Labels and Conjugation Process.

Authors:  Andreea-Cristina Mirica; Dana Stan; Ioana-Cristina Chelcea; Carmen Marinela Mihailescu; Augustin Ofiteru; Lorena-Andreea Bocancia-Mateescu
Journal:  Front Bioeng Biotechnol       Date:  2022-06-14

6.  Rapid Colorimetric Assay for Detection of Listeria monocytogenes in Food Samples Using LAMP Formation of DNA Concatemers and Gold Nanoparticle-DNA Probe Complex.

Authors:  Sirirat Wachiralurpan; Thayat Sriyapai; Supatra Areekit; Pichapak Sriyapai; Suphitcha Augkarawaritsawong; Somchai Santiwatanakul; Kosum Chansiri
Journal:  Front Chem       Date:  2018-04-03       Impact factor: 5.221

Review 7.  Advanced Signal-Amplification Strategies for Paper-Based Analytical Devices: A Comprehensive Review.

Authors:  Thi Xoan Hoang; Le Minh Tu Phan; Thuy Anh Thu Vo; Sungbo Cho
Journal:  Biomedicines       Date:  2021-05-12

Review 8.  Magnetic Lateral Flow Immunoassays.

Authors:  Amanda Moyano; Esther Serrano-Pertierra; María Salvador; José Carlos Martínez-García; Montserrat Rivas; M Carmen Blanco-López
Journal:  Diagnostics (Basel)       Date:  2020-05-08

9.  Optimization of isothermal amplification method for Mycobacteriumtuberculosisdetection and visualization method for fieldwork

Authors:  Hatice Esra Ağel; Hasan Sağcan; Ismail Ceyhan; Riza Durmaz
Journal:  Turk J Med Sci       Date:  2020-06-23       Impact factor: 0.973

10.  Instrumentation-Free Semiquantitative Immunoanalysis Using a Specially Patterned Lateral Flow Assay Device.

Authors:  Kyung Won Lee; Ye Chan Yu; Hyeong Jin Chun; Yo Han Jang; Yong Duk Han; Hyun C Yoon
Journal:  Biosensors (Basel)       Date:  2020-07-31
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.