Literature DB >> 26653429

PVDF-ErGO-GRC electrode: A single setup electrochemical system for separation, pre-concentration and detection of lead ions in complex aqueous samples.

Kunashegaran Hamsawahini1, Palanivel Sathishkumar2, Rahmalan Ahamad3, Abdull Rahim Mohd Yusoff4.   

Abstract

An effective electrode was developed based on electromembrane extraction (EME) and square wave voltammetry (SWV) for simultaneous separation, pre-concentration and determination of lead (II) (Pb(II)) ions in complex aqueous samples. Electrochemically reduced graphene oxide-graphite reinforced carbon (ErGO-GRC) was utilized in conjunction with the SWV. Pb(II) ions were extracted from an aqueous sample solution into an acidic acceptor phase (1M HCl) in the lumen of the polyvinylidene fluoride (PVDF) membrane bag by the application of voltage of maximum 6 V across the supported liquid membrane (SLM), consisting of organic solvent and di-(2-ethylhexyl)phosphoric acid (D2EHPA). The parameters affecting the EME were optimized for Pb(II) ions. The optimum EME conditions were found to be 20% D2EHPA in 1-octanol impregnated in the wall of PVDF membrane (PVDF17) as the SLM, extraction time of 20 min, pH of sample solution of 8 and a voltage of 5 V. The PVDF-ErGO-GRC electrode system attained enrichment factors of 40 times and 80% of extraction with relative standard deviations (n=5) of 8.3%. Good linearity ranging from 0.25 to 2 nM with coefficients correlation of 0.999 was obtained. The Pb(II) ions detection limit of PVDF-ErGO-GRC electrode was found to be 0.09 nM. The newly developed single setup electrochemical system was applied to complex aqueous samples such as tap, river and sea water to evaluate the feasibility of the method for applications.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Electromembrane extraction; Graphene oxide; Graphite reinforced carbon; Lead ions; Polyvinylidene fluoride; Square wave voltammetry

Mesh:

Substances:

Year:  2015        PMID: 26653429     DOI: 10.1016/j.talanta.2015.10.044

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  2 in total

Review 1.  Heavy metal pollution in immobile and mobile components of lentic ecosystems-a review.

Authors:  Ramakrishnan Anu Alias Meena; Palanivel Sathishkumar; Fuad Ameen; Abdull Rahim Mohd Yusoff; Feng Long Gu
Journal:  Environ Sci Pollut Res Int       Date:  2017-12-15       Impact factor: 4.223

2.  Sensitive Metal Oxide-Clay Nanocomposite Colorimetric Sensor Development for Aflatoxin Detection in Foods: Corn and Almond.

Authors:  Nishtha Khansili; Prayaga Murali Krishna
Journal:  ACS Omega       Date:  2021-06-03
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.