Brain perfusion evaluated by perfusion-weighted magnetic resonance imaging before and after stenting internal carotid artery stenosis in asymptomatic and symptomatic patients.

Maria Małowidzka-Serwińska1, Magdalena Żabicka2, Adam Witkowski3, Zbigniew Chmielak3, Tomasz Deptuch3.   

Abstract

PURPOSE: To evaluate the brain perfusion with MRI perfusion weighted imaging (PWI) before and after ICA stenting in asymptomatic and symptomatic patients.
MATERIALS AND METHODS: PWI was performed 3-21 days before and 3 days after ICA stenting in 31 asymptomatic patients with ICA >70% stenosis - Group I, and in 14 symptomatic patients with ICA >50% stenosis - Group II. PWI was evaluated qualitatively and quantitatively in 5 cerebral territories with: mean transit time (MTT), cerebral blood volume (CBV) and cerebral blood flow (CBF). Mean values of perfusion parameters were measured before and after stenting ΔMTT, ΔCBV, ΔCBF were calculated as subtraction of after-treatment values from those before treatment.
RESULTS: In qualitative evaluation after ICA stenting perfusion was normalized in 21 patients (80.8%) in Group I and in 8 patients (80%) in Group II. In quantitative estimation MTT decreased significantly after CAS on stented side vs. non-stented side in all examined patients regardless of the group, p<0.05. MTT decreased more in Group II than in Group I in all territories (p<0.05) with the exception of temporal lobe. CBV and CBF have shown insignificant differences.
Copyright © 2015 Polish Neurological Society. Published by Elsevier Urban & Partner Sp. z o.o. All rights reserved.

Entities:  

Keywords:  Carotid artery stenosis; Carotid stenting; Cerebral hemodynamics; Magnetic resonance imaging; Perfusion-weighted imaging

Mesh:

Year:  2015        PMID: 26652876     DOI: 10.1016/j.pjnns.2015.10.005

Source DB:  PubMed          Journal:  Neurol Neurochir Pol        ISSN: 0028-3843            Impact factor:   1.621


  2 in total

1.  Perfusion-weighted magnetic resonance imaging in the assessment of haemodynamics following stent angioplasty in patients with symptomatic middle cerebral artery plaque stenosis at the M1 segment.

Authors:  Yun-Cai Ran; Ming Zhu; Yong Zhang; Teng-Fei Li; Jing-Liang Cheng
Journal:  Exp Ther Med       Date:  2017-07-09       Impact factor: 2.447

2.  Multiple blood flow measurements before and after carotid artery stenting via phase-contrast magnetic resonance imaging: An observational study.

Authors:  Hisashi Tanaka; Yoshiyuki Watanabe; Hajime Nakamura; Hiroto Takahashi; Atsuko Arisawa; Takuya Fujiwara; Chisato Matsuo; Noriyuki Tomiyama
Journal:  PLoS One       Date:  2018-04-11       Impact factor: 3.240