Restoration of sinus rhythm and atrial transport function after the maze procedure: U lesion set versus box lesion set.

Takashi Nitta1, Yosuke Ishii2, Masahiro Fujii2, Yasuo Miyagi2, Shun-Ichiro Sakamoto2, Atsushi Hiromoto2, Hajime Imura2.   

Abstract

OBJECTIVE: In a U lesion set, the left atrium (LA) roof between the right and left superior pulmonary veins is not ablated, to allow activation to propagate across the posterior LA and to recruit this segment as a contractile atrial component. In contrast, the box lesion set isolates the entire posterior LA.
METHODS: To compare the two lesion sets, postoperative freedom from atrial fibrillation (AF) and LA transport function were examined in 402 patients who underwent surgery for AF with a U lesion (n = 329) or box lesion (n = 73) set. Patients who underwent pulmonary vein isolation alone or other simplified procedures were excluded from the study. LA transport function was quantified at 20 ± 33 months postoperatively by the ratio of peak velocity of the A wave to the E wave (peak A/E) of the transmitral Doppler flow.
RESULTS: In patients with long-standing persistent AF, freedom from AF was 85% with the U lesion set and 77% with the box lesion set at 5 years after the maze procedure, and 82% and 77%, respectively, at 10 years after the procedure. There was no significant difference between the U lesion set and box lesion set in patients with long-standing persistent AF (P = .30) and those with paroxysmal or persistent AF (P = .90). Proportional hazards analysis identified increased LA diameter (P = .003) and long-standing persistent AF (P = .03), but not the type of lesion set (P = .51), as predictive of postoperative AF recurrence. The postoperative peak A/E was significantly greater after the U lesion set than after the box lesion set (0.42 ± 0.22 vs 0.23 ± 0.17), and multiple regression analysis demonstrated that the type of lesion set and preoperative LA diameter significantly affected postoperative A/E.
CONCLUSIONS: The U lesion set restores sinus rhythm frequently as the box lesion set and provides better LA transport function. A dilated LA is a risk factor for postoperative recurrence of AF and poor postoperative LA transport function.
Copyright © 2016 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  lesion set; posterior LA; transport function

Mesh:

Year:  2015        PMID: 26651965     DOI: 10.1016/j.jtcvs.2015.10.108

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  2 in total

Review 1.  Development of the Maze procedure and the contribution of Japanese surgeons.

Authors:  Shinya Takahashi; Taijiro Sueda
Journal:  Gen Thorac Cardiovasc Surg       Date:  2016-11-16

2.  Multicenter randomized study evaluating the outcome of ganglionated plexi ablation in maze procedure.

Authors:  Shun-Ichiro Sakamoto; Yosuke Ishii; Toshiaki Otsuka; Masataka Mitsuno; Tomoki Shimokawa; Tadashi Isomura; Hitoshi Yaku; Tatsuhiko Komiya; Goro Matsumiya; Takashi Nitta
Journal:  Gen Thorac Cardiovasc Surg       Date:  2022-04-27
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.