The Reliability of Anthropometric Measurements Used Preoperatively in Aesthetic Breast Surgery.

Kathryn V Isaac1, Blake D Murphy1, Brett Beber1, Mitchell Brown1.   

Abstract

BACKGROUND: Patient outcomes in aesthetic breast surgery are highly dependent on breast measurements used in preoperative planning.
OBJECTIVES: The purpose of this study is to determine the reliability of anthropometric breast measurements.
METHODS: Four raters measured 28 women using 7 measurements: sternal notch to nipple distance (Sn-N), nipple to midline (N-M), nipple to inframammary-fold distance under maximal stretch (N-IMF), breast base width (BW), soft tissue pinch thickness of the upper pole (STPT:UP), STPT at the inframammary fold (STPT:IMF), and anterior pull skin stretch (APSS). Reliability was assessed using intra-class correlation coefficients (ICCs).
RESULTS: Inter-rater reliability was excellent for Sn-N, N-M, and BW (ICC = 0.94, 0.90, and 0.76, respectively) and was good for N-IMF (ICC = 0.70). The STPT:UP, STPT:IMF, and APSS measurements were not reliable between raters (ICC < 0.2). Intra-rater reliability was excellent for Sn-N, N-M, and BW for all raters (all ICC > 0.75). The N-IMF intra-rater reliability was excellent in senior raters (ICC > 0.75) and good in junior raters (ICC > 0.6). The STPT:UP, STPT:IMF, and APSS measurements showed fair or poor reliability for most raters (ICC < 0.6).
CONCLUSIONS: The Sn-N, N-M, and BW measurements are very reliable. Dynamic measurements including APSS, STPT:UP, and STUP:IMF are unreliable. N-IMF is the only reliable dynamic measurement, and its reliability improves with increasing clinical experience. The variable reliability of preoperative measurements must be considered in the planning of aesthetic breast surgery. LEVEL OF EVIDENCE: 4 Diagnostic.
© 2015 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com.

Entities:  

Mesh:

Year:  2015        PMID: 26647138     DOI: 10.1093/asj/sjv210

Source DB:  PubMed          Journal:  Aesthet Surg J        ISSN: 1090-820X            Impact factor:   4.283


  3 in total

Review 1.  Optimizing perioperative strategies to maximize success with prepectoral breast reconstruction.

Authors:  Dhivya R Srinivasa; Michael Holland; Hani Sbitany
Journal:  Gland Surg       Date:  2019-02

2.  Photometric Evaluation of Long-term Changes in Breast Shape after Breast Augmentation and Vertical Mammaplasty.

Authors:  Eric Swanson
Journal:  Plast Reconstr Surg Glob Open       Date:  2018-06-18

3.  Subpectoral Implant Repositioning With Partial Capsule Preservation: Treating the Long-Term Complications of Subglandular Breast Augmentation.

Authors:  Adam T Hauch; Cameron S Francis; Jourdain D Artz; Paul E Chasan
Journal:  Aesthet Surg J Open Forum       Date:  2021-03-02
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.