Literature DB >> 26643181

Neonatal complications associated with use of fetal scalp electrode: a retrospective study.

T Kawakita1, U M Reddy2, H J Landy3, S N Iqbal2, C-C Huang4, K L Grantz2.   

Abstract

OBJECTIVES: To estimate the incidence and risk of complications associated with a fetal scalp electrode and to determine whether its application in the setting of operative vaginal delivery was associated with increased neonatal morbidity.
DESIGN: Retrospective cohort study.
SETTING: Twelve clinical centers with 19 hospitals across nine American Congress of Obstetricians and Gynecologists US districts. POPULATION: Women in the USA.
METHODS: We evaluated 171 698 women with singleton deliveries ≥ 23 weeks of gestation in a secondary analysis of the Consortium on Safe Labor study between 2002 and 2008, after excluding conditions that precluded fetal scalp electrode application such as prelabour caesarean delivery. Secondary analysis limited to operative vaginal deliveries ≥ 34 weeks of gestation was also performed. MAIN OUTCOME MEASURES: Incidences and adjusted odds ratios with 95% confidence intervals of neonatal complications were calculated, controlling for maternal characteristics, delivery mode and pregnancy complications.
RESULTS: Fetal scalp electrode was used in 37 492 (22%) of deliveries. In non-operative vaginal delivery, fetal scalp electrode was associated with increased risk of injury to scalp due to birth trauma (1.2% versus 0.9%; adjusted odds ratios 1.62; 95% confidence intervals 1.41-1.86) and cephalohaematoma (1.0% versus 0.9%; adjusted odds ratios 1.57; 95% confidence intervals 1.36-1.83). Neonatal complications were not significantly different comparing fetal scalp electrode with vacuum-assisted vaginal delivery and vacuum-assisted vaginal delivery alone or comparing fetal scalp electrode with forceps-assisted vaginal delivery and forceps-assisted vaginal delivery alone.
CONCLUSIONS: We found increased neonatal morbidity with fetal scalp electrode though the absolute risk was very low. It is possible that these findings reflect an underlying indication for its use. Our findings support the use of fetal scalp electrodes when clinically indicated. TWEETABLE ABSTRACT: Neonatal risks associated with fetal scalp electrode use were low (injury to scalp 1.2% and cephalohaematoma 1.0%).
© 2015 Royal College of Obstetricians and Gynaecologists.

Entities:  

Keywords:  Cephalohaematoma; fetal scalp electrode; scalp injury

Mesh:

Year:  2015        PMID: 26643181      PMCID: PMC4899296          DOI: 10.1111/1471-0528.13817

Source DB:  PubMed          Journal:  BJOG        ISSN: 1470-0328            Impact factor:   6.531


  15 in total

1.  ACOG Practice Bulletin No. 86: Viral hepatitis in pregnancy.

Authors: 
Journal:  Obstet Gynecol       Date:  2007-10       Impact factor: 7.661

2.  ACOG Practice Bulletin No. 106: Intrapartum fetal heart rate monitoring: nomenclature, interpretation, and general management principles.

Authors: 
Journal:  Obstet Gynecol       Date:  2009-07       Impact factor: 7.661

3.  Scalp changes after fetal monitoring.

Authors:  S Ashkenazi; A Metzker; P Merlob; J Ovadia; S H Reisner
Journal:  Arch Dis Child       Date:  1985-03       Impact factor: 3.791

4.  Contemporary cesarean delivery practice in the United States.

Authors:  Jun Zhang; James Troendle; Uma M Reddy; S Katherine Laughon; D Ware Branch; Ronald Burkman; Helain J Landy; Judith U Hibbard; Shoshana Haberman; Mildred M Ramirez; Jennifer L Bailit; Matthew K Hoffman; Kimberly D Gregory; Victor H Gonzalez-Quintero; Michelle Kominiarek; Lee A Learman; Christos G Hatjis; Paul van Veldhuisen
Journal:  Am J Obstet Gynecol       Date:  2010-08-12       Impact factor: 8.661

5.  Gynaecological and obstetric management of women with inherited bleeding disorders.

Authors:  Christine Demers; Christine Derzko; Michèle David; Joanne Douglas
Journal:  Int J Gynaecol Obstet       Date:  2006-10       Impact factor: 3.561

6.  Mortality from early neonatal group B streptococcal sepsis: influence of obstetric factors.

Authors:  P Gill; J Sobeck; D Jarjoura; S Hillier; T Benedetti
Journal:  J Matern Fetal Med       Date:  1997 Jan-Feb

7.  Births: final data for 2012.

Authors:  Joyce A Martin; Brady E Hamilton; Michelle J K Osterman; Sally C Curtin; T J Matthews
Journal:  Natl Vital Stat Rep       Date:  2013-12-30

8.  Septic dermatitis of the neonatal scalp and maternal endomyometritis with intrapartum internal fetal monitoring.

Authors:  M M Wagener; R R Rycheck; R B Yee; J F McVay; C L Buffenmyer; J H Harger
Journal:  Pediatrics       Date:  1984-07       Impact factor: 7.124

9.  Scalp abscess: a benign and infrequent complication of fetal monitoring.

Authors:  L Cordero; C W Anderson; F P Zuspan
Journal:  Am J Obstet Gynecol       Date:  1983-05-15       Impact factor: 8.661

10.  Neonatal scalp abscess and fetal monitoring: factors associated with infection.

Authors:  D M Okada; A W Chow; V T Bruce
Journal:  Am J Obstet Gynecol       Date:  1977-09-15       Impact factor: 8.661

View more
  5 in total

1.  Use and experiences with external fetal monitoring devices among obstetrical providers.

Authors:  Alan J Rosenbaum; Rachel M Smith; Erinn M Hade; Ashish Gupta; Alper Yilmaz; Michael Cackovic
Journal:  J Matern Fetal Neonatal Med       Date:  2018-12-12

2.  Non-invasive Fetal Electrocardiography for Intrapartum Cardiotocography.

Authors:  Rik Vullings; Judith O E H van Laar
Journal:  Front Pediatr       Date:  2020-12-09       Impact factor: 3.418

3.  Machine Learning Model for Classifying the Results of Fetal Cardiotocography Conducted in High-Risk Pregnancies.

Authors:  Tae Jun Park; Hye Jin Chang; Byung Jin Choi; Jung Ah Jung; Seongwoo Kang; Seokyoung Yoon; Miran Kim; Dukyong Yoon
Journal:  Yonsei Med J       Date:  2022-07       Impact factor: 3.052

Review 4.  Sensors for Fetal Hypoxia and Metabolic Acidosis: A Review.

Authors:  Gerard Cummins; Jessica Kremer; Anne Bernassau; Andrew Brown; Helen L Bridle; Holger Schulze; Till T Bachmann; Michael Crichton; Fiona C Denison; Marc P Y Desmulliez
Journal:  Sensors (Basel)       Date:  2018-08-13       Impact factor: 3.576

5.  Neonatal brain abscess development following fetal scalp electrode placement: a rare complication.

Authors:  T Fick; P A Woerdeman
Journal:  Childs Nerv Syst       Date:  2021-04-06       Impact factor: 1.475

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.