Cui Liu1, Zhen Zhou1, Linling Zou1, Yuan-Cheng Cao2, Jun'An Liu3, Yongjun Lin4.
Abstract
A highly sensitive transgenic protein analysis method was proposed here based on fluorescein diacetate (FDA). First, FDA was prepared by the ball mill to harvest the nano-sized organic particles. Further examines showed that the FDA size can be controlled by the speed of centrifugation which can obtain FDA in well-distributed size. Cy3 antibody immobilization tests showed that the proteins can attach onto the FDA particles while keep bioactivities. FDA and Cry1Ac antibody immunoassay tests showed that when the FDA particle was in 150 nm, the linear range was 0.01 ng/L-30 μg/mL. And it has the lower detection limitation of 0.01 ng/L, which is 100 times more sensitive than the ELISA methods. These results indicate that the FDA related immunoassays are the promising approach in the transgenic analysis.Entities:
Keywords: Cry1Ac protein; Fluorescein diacetate; Fluorescent analysis; Immunoassay
Mesh:
Substances:
Year: 2015 PMID: 26642804 DOI: 10.1007/s10895-015-1731-x