Literature DB >> 26642315

Wearable ECG Based on Impulse-Radio-Type Human Body Communication.

Jianqing Wang, Takuya Fujiwara, Taku Kato, Daisuke Anzai.   

Abstract

Human body communication (HBC) provides a promising physical layer for wireless body area networks (BANs) in healthcare and medical applications, because of its low propagation loss and high security characteristics. In this study, we have developed a wearable electrocardiogram (ECG) which employs impulse radio (IR)-type HBC technology for transmitting vital signals on the human body in a wearable BAN scenario. The HBC-based wearable ECG has two excellent features. First, the wideband performance of the IR scheme contributed to very low radiation power so that the transceiver is easy to satisfy the extremely weak radio laws, which does not need a license. This feature can provide big convenience in the use and spread of the wearable ECG. Second, the realization of common use of sensing and transmitting electrodes based on time sharing and capacitive coupling largely simplified the HBC-based ECG structure and contributed to its miniaturization. To verify the validity of the HBC-based ECG, we evaluated its communication performance and ECG acquisition performance. The measured bit error rate, smaller than 10 -3 at 1.25 Mb/s, showed a good physical layer communication performance, and the acquired ECG waveform and various heart-rate variability parameters in time and frequency domains exhibited good agreement with a commercially available radio-frequency ECG and a Holter ECG. These results sufficiently showed the validity and feasibility of the HBC-based ECG for healthcare applications. This should be the first time to have realized a real-time ECG transmission by using the HBC technology.

Entities:  

Mesh:

Year:  2015        PMID: 26642315     DOI: 10.1109/TBME.2015.2504998

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  4 in total

1.  Performance of human body communication-based wearable ECG with capacitive coupling electrodes.

Authors:  Jun Sakuma; Daisuke Anzai; Jianqing Wang
Journal:  Healthc Technol Lett       Date:  2016-07-05

2.  Non-Contact Heart-Rate Measurement Method Using Both Transmitted Wave Extraction and Wavelet Transform.

Authors:  Zheng Yang; Kazutaka Mitsui; Jianqing Wang; Takashi Saito; Shunsuke Shibata; Hiroyuki Mori; Goro Ueda
Journal:  Sensors (Basel)       Date:  2021-04-13       Impact factor: 3.576

3.  Flexible Non-contact Electrodes for Wearable Biosensors System on Electrocardiogram Monitoring in Motion.

Authors:  Xin Wang; Shuting Liu; Mingxing Zhu; Yuchao He; Zhilong Wei; Yingying Wang; Yangjie Xu; Hongguang Pan; Weimin Huang; Shixiong Chen; Guanglin Li
Journal:  Front Neurosci       Date:  2022-06-07       Impact factor: 5.152

4.  Motion artefact removals for wearable ECG using stationary wavelet transform.

Authors:  Shuto Nagai; Daisuke Anzai; Jianqing Wang
Journal:  Healthc Technol Lett       Date:  2017-06-14
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.