| Literature DB >> 2664057 |
P J Wade1, R G Wetherell, A A Amis.
Abstract
A biomechanical study in vitro has evaluated a new modification of the core and peripheral suture technique for flexor tendon repair. Groups of repairs were conducted in cadaver tendons, using a core suture alone, a core suture with a simple running surface suture and a new modification involving a 'Halsted' horizontal mattress technique for the peripheral stitch. The Halsted modification increased the load at which a visible gap formed by 93%, the load at which a 2 mm gap formed by 77%, and the maximum strength by 89%. This increase was due to the technique; it did not depend on the suture material used. The bulk of the tendon repair was not significantly greater with the Halsted modification.Mesh:
Year: 1989 PMID: 2664057 DOI: 10.1016/0266-7681(89)90135-6
Source DB: PubMed Journal: J Hand Surg Br ISSN: 0266-7681