Literature DB >> 26638872

Early Recurrence After Pulmonary Vein Isolation of Paroxysmal Atrial Fibrillation With Different Ablation Technologies - Prospective Comparison of Radiofrequency vs. Second-Generation Cryoballoon Ablation.

Shinsuke Miyazaki1, Akio Kuroi, Hitoshi Hachiya, Hiroaki Nakamura, Hiroshi Taniguchi, Noboru Ichihara, Takamitsu Takagi, Jin Iwasawa, Yoshito Iesaka.   

Abstract

BACKGROUND: Inflammation plays a prominent role in the etiology of the early recurrence of atrial fibrillation (ERAF). We prospectively compared the proportion of ERAF and time-course patterns of biomarkers between radiofrequency (RF) and cryoballoon (CB) ablation. METHODS AND 
RESULTS: We enrolled 82 consecutive paroxysmal AF patients undergoing pulmonary vein (PV) isolation, performed with either a 28-mm 2nd-generation CB and 3-min freeze technique or point-by-point RF ablation. Each group had 41 patients. In the RF group, all PVs were successfully isolated with 28.9 ± 6.5 min of RF delivery. In the CB group, a mean of 5.3 ± 1.4 applications/patient was delivered. The proportion of ERAF was similar between the groups. The time-course patterns significantly differed between the groups for high-sensitivity C-reactive protein (hs-CRP) value (P=0.006) and myocardial injury markers (P<0.0001). Greater myocardial injury was observed in the CB than in the RF group (P<0.0001), whereas the peak hs-CRP value was comparable between the groups. The 2-day post-procedure hs-CRP value was the sole factor correlating with ERAF as identified by the multivariable analysis (hazard ratio 1.697; 95% confidence interval, 1.005-2.865; P=0.048) in the RF, but not the CB group.
CONCLUSIONS: The proportion of ERAF was comparable after RF and 2nd-generation CB ablation. Despite CB ablation exhibiting greater myocardial injury than RF ablation, the inflammatory responses were comparable between the groups. The inflammatory response extent predicted ERAF post-RF ablation but not post-CB ablation.

Entities:  

Mesh:

Year:  2015        PMID: 26638872     DOI: 10.1253/circj.CJ-15-1051

Source DB:  PubMed          Journal:  Circ J        ISSN: 1346-9843            Impact factor:   2.993


  14 in total

Review 1.  Comparison of catheter ablation for paroxysmal atrial fibrillation between cryoballoon and radiofrequency: a meta-analysis.

Authors:  Chao-Feng Chen; Xiao-Fei Gao; Xu Duan; Bin Chen; Xiao-Hua Liu; Yi-Zhou Xu
Journal:  J Interv Card Electrophysiol       Date:  2017-01-07       Impact factor: 1.900

2.  Early Recurrences During the Blanking Period after Atrial Fibrillation Ablation.

Authors:  Jackson J Liang; Sanjay Dixit
Journal:  J Atr Fibrillation       Date:  2018-02-28

3.  Early recurrence during the blanking period and left atrial reverse remodeling after catheter ablation for non-paroxysmal atrial fibrillation.

Authors:  Takafumi Oka; Yasushi Koyama; Koji Tanaka; Yuko Hirao; Nobuaki Tanaka; Masato Okada; Issei Yoshimoto; Ryo Kitagaki; Atsunori Okamura; Katsuomi Iwakura; Yasushi Sakata; Kenshi Fujii; Koichi Inoue
Journal:  Int J Cardiol Heart Vasc       Date:  2020-07-23

Review 4.  Efficacy and safety of the second-generation cryoballoons versus radiofrequency ablation for the treatment of paroxysmal atrial fibrillation: a systematic review and meta-analysis.

Authors:  Jingbo Jiang; Jinyi Li; Guoqiang Zhong; Junjun Jiang
Journal:  J Interv Card Electrophysiol       Date:  2016-09-28       Impact factor: 1.900

5.  Transient manifestation of left ventricular diastolic dysfunction following ablation in patients with paroxysmal atrial fibrillation.

Authors:  Tomoko Minamisaka; Tetsuya Watanabe; Yukinori Shinoda; Kuniyasu Ikeoka; Hidetada Fukuoka; Hirooki Inui; Keisuke Ueno; Soki Inoue; Kentaro Mine; Shiro Hoshida
Journal:  Clin Cardiol       Date:  2018-07-18       Impact factor: 2.882

Review 6.  Radiofrequency Ablation versus Cryoablation in the Treatment of Paroxysmal Atrial Fibrillation: A Meta-Analysis.

Authors:  Ali H Hachem; Joseph E Marine; Housam A Tahboub; Sana Kamdar; Shaffi Kanjwal; Ronak Soni; Khalil Kanjwal
Journal:  Cardiol Res Pract       Date:  2018-04-01       Impact factor: 1.866

7.  The relationship of early recurrence of atrial fibrillation and the 3-month integrity of the ablation lesion set.

Authors:  Nebojša Mujović; Milan Marinković; Nebojša Marković; Vera Vučićević; Gregory Y H Lip; T Jared Bunch; Tatjana S Potpara
Journal:  Sci Rep       Date:  2018-06-29       Impact factor: 4.379

Review 8.  Cryoballoon Ablation for Atrial Fibrillation: a Comprehensive Review and Practice Guide.

Authors:  Eun Sun Jin; Paul J Wang
Journal:  Korean Circ J       Date:  2018-02       Impact factor: 3.243

Review 9.  Mechanisms and clinical significance of early recurrences of atrial arrhythmias after catheter ablation for atrial fibrillation.

Authors:  Jackson J Liang; Sanjay Dixit; Pasquale Santangeli
Journal:  World J Cardiol       Date:  2016-11-26

10.  Circulatory Dynamics During Pulmonary Vein Isolation Using the Second-Generation Cryoballoon.

Authors:  Takatsugu Kajiyama; Shinsuke Miyazaki; Tomonori Watanabe; Kazuya Yamao; Shigeki Kusa; Miyako Igarashi; Hiroaki Nakamura; Hitoshi Hachiya; Yoshito Iesaka
Journal:  J Am Heart Assoc       Date:  2017-10-10       Impact factor: 5.501

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.