Literature DB >> 26637966

Google Glass Glare: disability glare produced by a head-mounted visual display.

Chris Longley1, David Whitaker2.   

Abstract

PURPOSE: Head mounted displays are a type of wearable technology - a market that is projected to expand rapidly over the coming years. Probably the most well known example is the device Google Glass (or 'Glass'). Here we investigate the extent to which the device display can interfere with normal visual function by producing monocular disability glare.
METHODS: Contrast sensitivity was measured in two normally sighted participants, 32 and 52 years of age. Data were recorded for the right eye, the left eye and then again in a binocular condition. Measurements were taken both with and without the Glass in place, across a range of stimulus luminance levels using a two-alternative forced-choice methodology.
RESULTS: The device produced a significant reduction in contrast sensitivity in the right eye (>0.5 log units). The level of disability glare increased as stimulus luminance was reduced in a manner consistent with intraocular light scatter, resulting in a veiling retinal illuminance. Sensitivity in the left eye was unaffected. A significant reduction in binocular contrast sensitivity occurred at lower luminance levels due to a loss of binocular summation, although binocular sensitivity was not found to fall below the sensitivity of the better monocular level (binocular inhibition).
CONCLUSIONS: Head mounted displays such as Google Glass have the potential to cause significant disability glare in the eye exposed to the visual display, particularly under conditions of low luminance. They can also cause a more modest binocular reduction in sensitivity by eliminating the benefits of binocular summation.
© 2015 The Authors Ophthalmic & Physiological Optics © 2015 The College of Optometrists.

Entities:  

Keywords:  Google Glass; binocular inhibition; binocular summation; contrast sensitivity; disability glare

Mesh:

Year:  2015        PMID: 26637966     DOI: 10.1111/opo.12264

Source DB:  PubMed          Journal:  Ophthalmic Physiol Opt        ISSN: 0275-5408            Impact factor:   3.117


  4 in total

1.  Feasibility of remote administration of the fundamentals of laparoscopic surgery (FLS) skills test using Google wearable device.

Authors:  Anton Nikouline; M Carolina Jimenez; Allan Okrainec
Journal:  Surg Endosc       Date:  2019-04-29       Impact factor: 4.584

2.  Evaluation of Google Glass Technical Limitations on Their Integration in Medical Systems.

Authors:  Antonio Martinez-Millana; Jose-Luis Bayo-Monton; Aroa Lizondo; Carlos Fernandez-Llatas; Vicente Traver
Journal:  Sensors (Basel)       Date:  2016-12-15       Impact factor: 3.576

3.  The Effect of a Head-mounted Low Vision Device on Visual Function.

Authors:  Walter Wittich; Marie-Céline Lorenzini; Samuel N Markowitz; Michael Tolentino; Scott A Gartner; Judith E Goldstein; Gislin Dagnelie
Journal:  Optom Vis Sci       Date:  2018-09       Impact factor: 1.973

4.  Binocular summation revisited: Beyond √2.

Authors:  Daniel H Baker; Freya A Lygo; Tim S Meese; Mark A Georgeson
Journal:  Psychol Bull       Date:  2018-08-13       Impact factor: 17.737

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.