Literature DB >> 26632785

Comparison of Traditional and Integrated Digital Anesthetic Vaporizers.

Frederick W Damen1, Amelia R Adelsperger1, Katherine E Wilson2, Craig J Goergen3.   

Abstract

Recent efforts have focused on mitigating anesthetic gas emissions during laboratory animal experiments. A recently developed, digitally controlled, integrated digital vaporizer (IDV) using a syringe pump has been designed to use and administer anesthetic gas to mice and rats more efficiently. The entire IDV system can be placed on a laboratory bench, requires fewer charcoal filters to act as passive scavengers when used at a low gas flow rate, and does not need compressed gas to operate, a requirement for traditional passive systems. The objective of this study was to compare isoflurane usage between a traditional vaporizer (TdV) and an IDV system at both the same settings and those recommended by the manufacturer. We used 10 C57BL/6 male mice and administered isoflurane through either nose cones or tracheal tubes connected to a pulsatile ventilator. The results showed that isoflurane usage is highly dependent on the flow rate of the carrier gas, but the IDV system was more precise and handled low flow rates (150 mL/min) better than did the TdV system. We observed only slight differences in heart rate, respiration rate, core body temperature, time to loss of the righting reflex, and recovery time between group averages for both systems when set to manufacturer-recommended settings. Although observed decreased levels of waste anesthetic gas at low flow rates are expected from the IDV system, further work is needed to assess environmental anesthetic gas levels and exposure to laboratory personnel.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26632785      PMCID: PMC4671791     

Source DB:  PubMed          Journal:  J Am Assoc Lab Anim Sci        ISSN: 1559-6109            Impact factor:   1.232


  25 in total

1.  Waste anaesthetic gases induce sister chromatid exchanges in lymphocytes of operating room personnel.

Authors:  K H Hoerauf; G Wiesner; K F Schroegendorfer; B P Jobst; A Spacek; M Harth; S Sator-Katzenschlager; H W Rüdiger
Journal:  Br J Anaesth       Date:  1999-05       Impact factor: 9.166

2.  Considerations in the design and function of anesthetic vaporizers.

Authors:  L E MORRIS; S A FELDMAN
Journal:  Anesthesiology       Date:  1958 Sep-Oct       Impact factor: 7.892

3.  A new vaporizer for liquid anesthetic agents.

Authors:  L E MORRIS
Journal:  Anesthesiology       Date:  1952-11       Impact factor: 7.892

Review 4.  Inhaled anesthetic agents.

Authors:  Joan Stachnik
Journal:  Am J Health Syst Pharm       Date:  2006-04-01       Impact factor: 2.637

5.  Pharmacologic resuscitation decreases circulating cytokine-induced neutrophil chemoattractant-1 levels and attenuates hemorrhage-induced acute lung injury.

Authors:  Eugene Y Fukudome; Yongqing Li; Ashley R Kochanek; Jennifer Lu; Eleanor J Smith; Baoling Liu; Kyuseok Kim; George C Velmahos; Marc A deMoya; Hasan B Alam
Journal:  Surgery       Date:  2012-05-30       Impact factor: 3.982

6.  Mouse strain modestly influences minimum alveolar anesthetic concentration and convulsivity of inhaled compounds.

Authors:  J M Sonner; D Gong; J Li; E I Eger; M J Laster
Journal:  Anesth Analg       Date:  1999-10       Impact factor: 5.108

7.  Pyruvate is superior to reverse visceral hypoperfusion in peritoneal resuscitation from hemorrhagic shock in rats.

Authors:  Sen Hu; Li Ma; Hong-Min Luo; Zhi-Long Lin; Xiao-Qing Wang; Yan-Hua Jia; Xiao-Dong Bai; Fang-Qiang Zhou; Zhi-Yong Sheng
Journal:  Shock       Date:  2014-04       Impact factor: 3.454

8.  Increased anterior abdominal aortic wall motion: possible role in aneurysm pathogenesis and design of endovascular devices.

Authors:  Craig J Goergen; Bonnie L Johnson; Joan M Greve; Charles A Taylor; Christopher K Zarins
Journal:  J Endovasc Ther       Date:  2007-08       Impact factor: 3.487

9.  Vital signs monitoring during injectable and inhalant anesthesia in mice.

Authors:  Atsushi Tsukamoto; Kazuya Serizawa; Reiichiro Sato; Jumpei Yamazaki; Tomo Inomata
Journal:  Exp Anim       Date:  2014-10-10

10.  Venous endothelin guides sympathetic innervation of the developing mouse heart.

Authors:  Eleana Manousiouthakis; Monica Mendez; Madeline C Garner; Prisca Exertier; Takako Makita
Journal:  Nat Commun       Date:  2014-05-29       Impact factor: 14.919

View more
  12 in total

1.  Use of an Integrated Low-Flow Anesthetic Vaporizer, Ventilator, and Physiological Monitoring System for Rodents.

Authors:  Krista Bigiarelli; Luke E Schepers; Arvin H Soepriatna; Dave FitzMiller; Craig J Goergen
Journal:  J Vis Exp       Date:  2020-07-09       Impact factor: 1.355

2.  In vivo photoacoustic lipid imaging in mice using the second near-infrared window.

Authors:  Gurneet S Sangha; Evan H Phillips; Craig J Goergen
Journal:  Biomed Opt Express       Date:  2017-01-10       Impact factor: 3.732

3.  Use of a Low-flow Digital Anesthesia System for Mice and Rats.

Authors:  Amelia R Adelsperger; Krista J Bigiarelli-Nogas; Irina Toore; Craig J Goergen
Journal:  J Vis Exp       Date:  2016-09-07       Impact factor: 1.355

4.  Cardiac and respiratory-gated volumetric murine ultrasound.

Authors:  Arvin H Soepriatna; Frederick W Damen; Pavlos P Vlachos; Craig J Goergen
Journal:  Int J Cardiovasc Imaging       Date:  2017-12-12       Impact factor: 2.357

5.  Improving characterization of hypertrophy-induced murine cardiac dysfunction using four-dimensional ultrasound-derived strain mapping.

Authors:  Frederick W Damen; John P Salvas; Andrea S Pereyra; Jessica M Ellis; Craig J Goergen
Journal:  Am J Physiol Heart Circ Physiol       Date:  2021-06-04       Impact factor: 5.125

6.  High-Frequency 4-Dimensional Ultrasound (4DUS): A Reliable Method for Assessing Murine Cardiac Function.

Authors:  Frederick W Damen; Alycia G Berman; Arvin H Soepriatna; Jessica M Ellis; Stephen D Buttars; Kristiina L Aasa; Craig J Goergen
Journal:  Tomography       Date:  2017-12

7.  Development of a Glycosaminoglycan Derived, Selectin Targeting Anti-Adhesive Coating to Treat Endothelial Cell Dysfunction.

Authors:  James R Wodicka; Andrea M Chambers; Gurneet S Sangha; Craig J Goergen; Alyssa Panitch
Journal:  Pharmaceuticals (Basel)       Date:  2017-03-29

8.  Adjustable photoacoustic tomography probe improves light delivery and image quality.

Authors:  Gurneet S Sangha; Nicholas J Hale; Craig J Goergen
Journal:  Photoacoustics       Date:  2018-08-22

9.  TRIO Platform: A Novel Low Profile In vivo Imaging Support and Restraint System for Mice.

Authors:  Vladislav Voziyanov; Benjamin S Kemp; Chelsea A Dressel; Kayla Ponder; Teresa A Murray
Journal:  Front Neurosci       Date:  2016-04-25       Impact factor: 4.677

10.  Pharmacological properties of various anesthetic protocols in 10-day-old neonatal rats.

Authors:  Atsushi Tsukamoto; Yui Konishi; Takako Kawakami; Chiharu Koibuchi; Reiichiro Sato; Eiichi Kanai; Tomo Inomata
Journal:  Exp Anim       Date:  2017-06-30
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.