Literature DB >> 26632197

Gait alterations can reduce the risk of edge loading.

Mariska Wesseling1, Christophe Meyer2, Friedl De Groote3, Kristoff Corten4, Jean-Pierre Simon5, Kaat Desloovere2, Ilse Jonkers1.   

Abstract

Following metal-on-metal hip arthroplasty, edge loading (i.e., loading near the edge of a prosthesis cup) can increase wear and lead to early revision. The position and coverage angle of the prosthesis cup influence the risk of edge loading. This study investigates the effect of altered gait patterns, more specific hip, and pelvis kinematics, on the orientation of hip contact force and the consequent risk of antero-superior edge loading using muscle driven simulations of gait. With a cup orientation of 25° anteversion and 50° inclination and a coverage angle of 168°, many gait patterns presented risk of edge loading. Specifically at terminal double support, 189 out of 405 gait patterns indicated a risk of edge loading. At this time instant, the high hip contact forces and the proximity of the hip contact force to the edge of the cup indicated the likelihood of the occurrence of edge loading. Although the cup position contributed most to edge loading, altering kinematics considerably influenced the risk of edge loading. Increased hip abduction, resulting in decreasing hip contact force magnitude, and decreased hip extension, resulting in decreased risk on edge loading, are gait strategies that could prevent edge loading.
© 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:1069-1076, 2016. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

Entities:  

Keywords:  edge loading; gait; hip arthroplasty; hip contact force

Mesh:

Year:  2015        PMID: 26632197     DOI: 10.1002/jor.23120

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  4 in total

1.  Increased Hip Stresses Resulting From a Cam Deformity and Decreased Femoral Neck-Shaft Angle During Level Walking.

Authors:  K C Geoffrey Ng; Giulia Mantovani; Mario Lamontagne; Michel R Labrosse; Paul E Beaulé
Journal:  Clin Orthop Relat Res       Date:  2017-04       Impact factor: 4.176

2.  Dysplastic hip anatomy alters muscle moment arm lengths, lines of action, and contributions to joint reaction forces during gait.

Authors:  Ke Song; Brecca M M Gaffney; Kevin B Shelburne; Cecilia Pascual-Garrido; John C Clohisy; Michael D Harris
Journal:  J Biomech       Date:  2020-07-25       Impact factor: 2.712

3.  Elevated loading at the posterior acetabular edge of dysplastic hips during double-legged squat.

Authors:  Ke Song; Cecilia Pascual-Garrido; John C Clohisy; Michael D Harris
Journal:  J Orthop Res       Date:  2022-01-11       Impact factor: 3.102

4.  Acetabular Edge Loading During Gait Is Elevated by the Anatomical Deformities of Hip Dysplasia.

Authors:  Ke Song; Cecilia Pascual-Garrido; John C Clohisy; Michael D Harris
Journal:  Front Sports Act Living       Date:  2021-07-01
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.