Literature DB >> 26627992

How Can We Help a Patient With a Small Failing Bioprosthesis?: An In Vitro Case Study.

Prem A Midha1, Vrishank Raghav1, Jose F Condado2, Sivakkumar Arjunon1, Domingo E Uceda1, Stamatios Lerakis2, Vinod H Thourani2, Vasilis Babaliaros2, Ajit P Yoganathan3.   

Abstract

OBJECTIVES: The aim of this study was to investigate the hemodynamic performance of a transcatheter heart valve (THV) deployed at different valve-in-valve positions in an in vitro model using a small surgical bioprosthesis.
BACKGROUND: Patients at high surgical risk with failing 19-mm surgical aortic bioprostheses are not candidates for valve-in-valve transcatheter aortic valve replacement, because of risk for high transvalvular pressure gradients (TVPGs) and patient-prosthesis mismatch.
METHODS: A 19-mm stented aortic bioprosthesis was mounted into the aortic chamber of a pulse duplicator, and a 23-mm low-profile balloon-expandable THV was deployed (valve-in-valve) in 4 positions: normal (bottom of the THV stent aligned with the bottom of the surgical bioprosthesis sewing ring) and 3, 6, and 8 mm above the normal position. Under controlled hemodynamic status, the effect of these THV positions on valve performance (mean TVPG, geometric orifice area, and effective orifice area), thrombotic potential (sinus shear stress), and migration risk (pullout force and embolization flow rate) were assessed.
RESULTS: Compared with normal implantation, a progressive reduction of mean TVPG was observed with each supra-annular THV position (normal: 33.10 mm Hg; 3 mm: 24.69 mm Hg; 6 mm: 19.16 mm Hg; and 8 mm: 12.98 mm Hg; p < 0.001). Simultaneously, we observed increases in geometric orifice area (normal: 0.83 cm(2); 8 mm: 1.60 cm(2); p < 0.001) and effective orifice area (normal: 0.80 cm(2); 8 mm: 1.28 cm(2); p < 0.001) and reductions in sinus shear stresses (normal: 153 dyne/cm(2); 8 mm: 40 dyne/cm(2); p < 0.001), pullout forces (normal: 1.55 N; 8 mm: 0.68 N; p < 0.05), and embolization flow rates (normal: 32.91 l/min; 8 mm: 26.06 l/min; p < 0.01).
CONCLUSIONS: Supra-annular implantation of a THV in a small surgical bioprosthesis reduces mean TVPG but may increase the risk for leaflet thrombosis and valve migration. A 3- to 6-mm supra-annular deployment could be an optimal position in these cases.
Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  small bioprosthesis; transcatheter aortic valve; valve-in-valve

Mesh:

Year:  2015        PMID: 26627992     DOI: 10.1016/j.jcin.2015.08.028

Source DB:  PubMed          Journal:  JACC Cardiovasc Interv        ISSN: 1936-8798            Impact factor:   11.195


  5 in total

Review 1.  On the Mechanics of Transcatheter Aortic Valve Replacement.

Authors:  Lakshmi P Dasi; Hoda Hatoum; Arash Kheradvar; Ramin Zareian; S Hamed Alavi; Wei Sun; Caitlin Martin; Thuy Pham; Qian Wang; Prem A Midha; Vrishank Raghav; Ajit P Yoganathan
Journal:  Ann Biomed Eng       Date:  2016-11-21       Impact factor: 3.934

2.  Optimising the Haemodynamics of Aortic Valve-in-valve Procedures.

Authors:  Ren Jie Yao; Matheus Simonato; Danny Dvir
Journal:  Interv Cardiol       Date:  2017-05

Review 3.  Principles of TAVR valve design, modelling, and testing.

Authors:  Oren M Rotman; Matteo Bianchi; Ram P Ghosh; Brandon Kovarovic; Danny Bluestein
Journal:  Expert Rev Med Devices       Date:  2018-10-29       Impact factor: 3.166

Review 4.  Transcatether Aortic Valve Implantation to Treat Degenerated Surgical Bioprosthesis: Focus on the Specific Procedural Challenges.

Authors:  Cristina Aurigemma; Francesco Burzotta; Rocco Vergallo; Piero Farina; Enrico Romagnoli; Stefano Cangemi; Francesco Bianchini; Marialisa Nesta; Piergiorgio Bruno; Domenico D'Amario; Antonio Maria Leone; Carlo Trani
Journal:  Front Cardiovasc Med       Date:  2022-05-31

Review 5.  Transcatheter Aortic and Mitral Valve-in-Valve Implantation Using the Edwards Sapien 3 Heart Valve.

Authors:  Anupama Shivaraju; Jonathan Michel; Antonio H Frangieh; Ilka Ott; Christian Thilo; Heribert Schunkert; Adnan Kastrati; Martin B Leon; Danny Dvir; Susheel Kodali; Vinayak Bapat; Mayra Guerrero; Albert M Kasel
Journal:  J Am Heart Assoc       Date:  2018-07-07       Impact factor: 5.501

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.