Literature DB >> 26620307

Transuncovertebral joint screw placement: technical note.

Tomoyuki Takigawa1, Masato Tanaka2, Takuya Morita2, Yoshihisa Sugimoto2, Ozaki Toshifumi2.   

Abstract

PURPOSE: Although a C2 pedicle screw and a C1-2 transarticular screw are the most rigid anchors, these screws cannot be used in cases with bilateral high-riding vertebral arteries. The authors describe their recent experience using a novel method of C2-3 transuncovertebral joint screw placement for occipitocervical fixation.
METHODS: A 67-year-old patient suffered myelopathy due to instability at C1-2. The patient had bilateral high-riding vertebral arteries that precluded the use of a C2 pedicle screw or a C1-2 transarticular screw.
RESULTS: A C2-3 transuncovertebral joint screw was applied bilaterally under 3D navigation guidance. The patient's postoperative course was uneventful, and his neurological status improved after the surgery. Bony fusion was achieved after the surgery.
CONCLUSIONS: This is the first report to describe the technique of transuncovertebral joint screw. Using a C2-3 transuncovertebral joint screw, a long screw could be used, and it provided an anchor at C3 and C2 from a posterior approach.

Entities:  

Keywords:  Cervical pedicle screw; Cervical spine; Navigation surgery; Transarticular screw; Uncovertebral joint

Mesh:

Year:  2015        PMID: 26620307     DOI: 10.1007/s00586-015-4343-x

Source DB:  PubMed          Journal:  Eur Spine J        ISSN: 0940-6719            Impact factor:   3.134


  10 in total

1.  Posterior C2 fixation using bilateral, crossing C2 laminar screws: case series and technical note.

Authors:  Neill M Wright
Journal:  J Spinal Disord Tech       Date:  2004-04

Review 2.  Reconstruction of the subaxial cervical spine using pedicle screw instrumentation.

Authors:  Kuniyoshi Abumi; Manabu Ito; Hideki Sudo
Journal:  Spine (Phila Pa 1976)       Date:  2012-03-01       Impact factor: 3.468

3.  The orientation of the articular facets of the zygapophyseal joints at the cervical and upper thoracic region.

Authors:  G P Pal; R V Routal; S K Saggu
Journal:  J Anat       Date:  2001-04       Impact factor: 2.610

4.  Cervical human vertebrae. Quantitative three-dimensional anatomy of the middle and lower regions.

Authors:  M M Panjabi; J Duranceau; V Goel; T Oxland; K Takata
Journal:  Spine (Phila Pa 1976)       Date:  1991-08       Impact factor: 3.468

Review 5.  The accuracy of pedicle screw placement using intraoperative image guidance systems.

Authors:  Alexander Mason; Renee Paulsen; Jason M Babuska; Sharad Rajpal; Sigita Burneikiene; E Lee Nelson; Alan T Villavicencio
Journal:  J Neurosurg Spine       Date:  2013-12-20

6.  Biomechanical effect of the C2 laminar decortication on the stability of C2 intralaminar screw construct and biomechanical comparison of C2 intralaminar screw and C2 pars screw.

Authors:  Jae Taek Hong; Tomoyuki Takigawa; Ranjith Udayakunmar; Hun Kyu Shin; Peter Simon; Alejandro A Espinoza Orías; Nozomu Inoue; Howard S An
Journal:  Neurosurgery       Date:  2011-09       Impact factor: 4.654

Review 7.  Biomechanical analysis of screw constructs for atlantoaxial fixation in cadavers: a systematic review and meta-analysis.

Authors:  Jerry Y Du; Alexander Aichmair; Janina Kueper; Timothy Wright; Darren R Lebl
Journal:  J Neurosurg Spine       Date:  2014-12-05

Review 8.  Reduction of atlantoaxial subluxation causes airway stenosis.

Authors:  Masanori Izeki; Masashi Neo; Hiromu Ito; Koutatsu Nagai; Tatsuro Ishizaki; Takeshi Okamoto; Shunsuke Fujibayashi; Mitsuru Takemoto; Hiroyuki Yoshitomi; Tomoki Aoyama; Shuichi Matsuda
Journal:  Spine (Phila Pa 1976)       Date:  2013-04-20       Impact factor: 3.468

9.  Operative management for atlantoaxial instability in case of bilateral high-riding vertebral artery.

Authors:  Dorothea Daentzer
Journal:  Arch Orthop Trauma Surg       Date:  2008-04-02       Impact factor: 3.067

10.  The O-C2 angle established at occipito-cervical fusion dictates the patient's destiny in terms of postoperative dyspnea and/or dysphagia.

Authors:  Masanori Izeki; Masashi Neo; Mitsuru Takemoto; Shunsuke Fujibayashi; Hiromu Ito; Koutatsu Nagai; Shuichi Matsuda
Journal:  Eur Spine J       Date:  2013-08-25       Impact factor: 3.134

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.